Perform Hydraulic Oil Analysis - Genie Z-34/22 Service Manual

Bi-energy power
Hide thumbs Also See for Z-34/22:
Table of Contents

Advertisement

April 2016
3
Using a mild solvent, carefully wash the cap
venting system. Dry using low pressure
compressed air. Repeat this procedure
beginning with step 2.
4
Install the fuel tank cap onto the fuel tank.
5
Remove the breather cap from the hydraulic
tank.
6
Check for proper venting.
Result: Air passes through the breather cap.
Proceed to step 8.
Result: If air does not pass through the cap,
clean or replace the cap. Proceed to step 7.
Note: When checking for positive tank cap venting,
air should pass freely through the cap.
7
Using a mild solvent, carefully wash the cap
venting system. Dry using low pressure
compressed air. Repeat this procedure
beginning with step 6.
8
Install the breather cap onto the hydraulic
tank.
Part No. 139234
Checklist B Procedures
B-18

Perform Hydraulic Oil Analysis

Genie specifications require that this procedure be
performed every 250 hours or quarterly, whichever
comes first.
Replacement or testing of the hydraulic oil is
essential for good machine performance and
service life. Dirty oil and a clogged suction strainer
may cause the machine to perform poorly and
continued use may cause component damage.
Extremely dirty conditions may require oil changes
to be performed more often. For hydraulic oil
specifications, Refer to Specifications, Hydraulic
Specifications.
Note: Before replacing the hydraulic oil, the oil may
be tested by an oil distributor for specific levels of
contamination to verify that changing the oil is
necessary. If the hydraulic oil is not replaced at the
two year inspection, test the oil quarterly. Replace
the oil when it fails the test. Refer to Maintenance
Procedure, Test or Replace the Hydraulic Oil.
Z-34/22 Bi-Energy