Toggle Switches; How To Test A Toggle Switch - Genie Z-34/22 Service Manual

Bi-energy power
Hide thumbs Also See for Z-34/22:
Table of Contents

Advertisement

Service Manual
Platform Controls
1-4

Toggle Switches

Toggle switches used for single function switching
are single pole double throw (SPDT) switches.
Dual function switching requires a double pole
double throw (DPDT) switch.

How to Test a Toggle Switch

How to T est a Toggle Switc h
Note: Continuity is the equivalent of 0 to 3 ohms. A
simple continuity tester may not accurately test the
switch.
This procedure covers fundamental switch testing
and does not specifically apply to all varieties of
toggle switches.
1
Turn the key switch to the off position. Tag and
disconnect all wiring from the toggle switch to
be tested.
2
Connect the leads of an ohmmeter to the
switch terminals in the following combinations
listed below to check for continuity.
Left
SPDT
DPDT
Note: Single pole double throw (SPDT). Double pole
double throw (DPDT)
60
Center
Right
Z-34/22 Bi-Energy
Test
Left position
terminal 1 to 2, 3, 4, 5 & 6
terminal 2 to 3
terminal 2 to 4, 5 & 6
terminal 3 to 4, 5 & 6
terminal 4 to 5 & 6
terminal 5 to 6
Center position
Right position
terminal 1 to 2
terminal 1 to 3, 4, 5 & 6
terminal 2 to 3, 4, 5 & 6
terminal 3 to 4, 5 & 6
terminal 4 to 5
terminal 4 to 6
terminal 5 to 6
April 2016
Desired result
no continuity (infinite Ω)
continuity (zero Ω)
no continuity
no continuity
no continuity
continuity
There are no terminal
combinations that will
produce continuity (infinite
Ω)
continuity(zero Ω)
no continuity(infinite Ω)
no continuity
no continuity
continuity
no continuity
no continuity
Part No. 139234