Range Reference Table; Range Reference Table (Q68Td-G-H02) - Mitsubishi Q68TD-G-H01 User Manual

Channel isolated thermocouple input module
Hide thumbs Also See for Q68TD-G-H01:
Table of Contents

Advertisement

7
ONLINE MODULE CHANGE
7.4

Range Reference Table

The range reference tables are given below.
7.4.1
Address (Decimal)
CH1
CH2
CH3
CH4
CH5
190
198
206
214
222
191
199
207
215
223
192
200
208
216
224
193
201
209
217
225
194
202
210
218
226
195
203
211
219
227
196
204
212
220
228
197
205
213
221
229
(1) Compare the factory default offset value with the reference value F868
(2) Compare the factory default gain value with the reference value 3640
(3) Compare the user range settings offset value with the value obtained from the
(4) Compare the user range settings gain value with the value obtained from the
(5) Obtain a value that corresponds to the offset setting temperature set by the
(6) Obtain a value that corresponds to the gain setting temperature set by the
7
- 33
7.4 Range Reference Table

7.4.1 Range reference table (Q68TD-G-H02)

Range reference table (Q68TD-G-H02)
CH6
CH7
CH8
230
238
246
Factory default offset value
231
239
247
Factory default gain value
232
240
248
User range settings offset value
233
241
249
User range settings gain value
234
242
250
User range settings thermal EMF offset value
235
243
251
User range settings thermal EMF offset value
236
244
252
User range settings thermal EMF gain value
237
245
253
User range settings thermal EMF gain value
following expression.
(Digital value) =
following expression.
User range settings thermal
(Digital value) =
EMF gain value ( V)
user from the chart of standard thermal electromotive force that is compliant
with JIS C 1602-1995, IEC584-1, and IEC584-2. Compare the value with the
user range settings offset thermal electromotive force value.
user from the chart of standard thermal electromotive force that is compliant
with JIS C 1602-1995, IEC584-1, and IEC584-2. Compare the value with the
user range settings gain thermal electromotive force value.
POINT
The chart of standard thermal electromotive force compliant with JIS C 1602-1995
and IEC584-1, or IEC584-2 needs to be arranged by the user.
Description
User range settings thermal
EMF offset value ( V)
Reference value
Digital value for offset value set prior to
shipment (Reference value F868
Digital value for gain value set prior to
shipment (Reference value 3640
Digital value for user-set offset value (Refer to
(3))
Digital value for user-set gain value (Refer to
(4))
(L)
Thermal EMF for user-set offset set
(H)
temperature ( V unit) (Refer to (5))
(L)
Thermal EMF for user-set gain set temperature
( V unit) (Refer to (6))
(H)
15832
45000
15832
45000
185
)
H
)
H
.
H
.
H
185