22 CONNECTOR INSTALLATION INSTRUCTIONS

22.1 Thermocouple Installation into a Backshell

Table 22-1 lists parts needed to install a Thermocouple, the item numbers correspond to Figure 22-1 and
Figure
22-2. Parts for this installation are included in the Thermocouple Kit (011-00981-00), which is
included in the G3X w/GSU 73 Installation Kit (K10-00017-00).
Item #
1
3" Thermocouple, K type
2
3
1. Strip back approximately 0.17 inches of insulation from both the positive and negative
thermocouple leads (item 1, Figure 22-1) and crimp a pin (item 2, Figure 22-1) to each lead. It is
the responsibility of the installer to determine the proper length of insulation to be removed. Wire
must be visible in the inspection hole after crimping and the insulation must be 1/64 – 1/32 inches
from the end of the contact as shown in Figure 22-1.
2
190-01115-01
Rev. AA
Table 22-1 Thermocouple Kit GPN 011-00981-00
Description
Pins #22 AWG
Screw
Figure 22-1 Insulation/Contact Clearance
G3X/G3X Touch Installation Manual - Connector Installation Instructions
Qty. Needed
1
2
1
1
PN or MIL spec
925-L0000-00
336-00021-00
211-60234-08
Page 22-1