Stall Warning AOA Calibration
This procedure sets the AOA value for the top of the red "chevron" section of the AOA gauge
(Figure 32-12), which is also the AOA value at which the audible stall warning sound will play
continuously (just before stall break is suggested).
1. Use the Touch Panel or a Move Selector Knob to select the Calibrated Stall Warning AOA
calibration field, then press the Calibrate button .
2. Follow the onscreen instructions, then press the Start button to begin the calibration.
3. Press the Done button when in compliance with the onscreen instructions.
190-01115-01 G3X/G3X Touch Install Manual - GDU 45X/46X Config and Post Install Checkout
Rev. AA
Stall Warning
AOA (Indicator
Flashes and Audio
Tone Sounds
Continuously)
Figure 32-12 Stall Warning AOA