23.13.6 Analog Input Configuration
Some analog inputs are multi-purpose capable and have several configuration options. These inputs are
configured by the GDU (refer to
GDU 45X/46X systems) and are capable of reading any voltage up to 40 Vdc.
NOTE
If installing an ungrounded thermocouple to an Analog In input, a DC reference must be
added to the LO input. This can be accomplished by adding a resistance of 1 MΩ or less
between ground and the Analog In LO input that the ungrounded thermocouple is installed
on.
Pin
Connector
61
J732
41
J732
21
J732
1
J732
2
J732
22
J732
60
J732
40
J732
73
J732
53
J732
33
J732
13
J732
63
J732
43
J732
23
J732
3
J732
24
J732
4
J732
62
J732
42
J732
30
J732
29
J732
34
J732
14
J732
72
J732
52
J732
25
J732
5
J732
190-01115-01
Rev. AA
Section 31.4.18
for GDU 37X systems and to
CHT 1 HI
CHT 1 LO
CHT 2 HI
CHT 2 LO
CHT 3 HI
CHT 3 LO
CHT 4 HI
CHT 4 LO
CHT 5 HI
CHT 5 LO
CHT 6 HI
CHT 6 LO
EGT 1 HI
EGT 1 LO
EGT 2 HI
EGT 2 LO
EGT 3 HI
EGT 3 LO
EGT 4 HI
EGT 4 LO
EGT 5 HI
EGT 5 LO
OIL TEMP HI
OIL TEMP LO
POS 5 / MISC TEMP HI
POS 5 / MISC TEMP LO
FUEL 1 HI
FUEL 1 LO
G3X/G3X Touch Installation Manual - LRU Pinouts
Section 32.4.25
Pin Name
for
I/O
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
Page 23-67