Figure 21-12 Tachometer Drive Output
UMA N/T1A9-X, JPI 4208XX
The magnetic pickup tach sensor is installed in the magneto bleed port. It is recommended that it be
installed in the non-impulse magneto, but it can be installed in the impulse magneto if only one magneto
exists (engines with single electronic ignition). The UMA N/T1A9-X sensors are suitable for non-
pressurized magnetos only. JPI 4208XX RPM sensors are available in different versions for both
pressurized and non-pressurized magnetos. Given that the bleed port size on Slick and Bendix magnetos
differ, the installer should verify that the sensor part number is appropriate for the magneto type.
1. Remove the existing vent plug from the magneto bleed port (Figure 21-14).
2. Lightly apply thread sealer such as Loctite 242 (or equivalent) to the threads of the sensor. Be
careful not to apply too much, and ensure sealer is applied only to the threads and not the pickup
face itself.
3. Install the sensor into the port (Figure 21-16). The sensor should be installed finger tight plus 1/6
turn. Do not over-tighten.
4. Connect the supplied connector to the appropriate inputs on the GEA 24/GSU 73 as referenced in
the G3X interconnects in
location in the engine compartment to provide strain relief.
190-01115-01
Rev. AA
Section
28. Secure the connector and wire assembly to an appropriate
Figure 21-14 Magneto Bleed Port
G3X/G3X Touch Installation Manual - Engine/Airframe Sensor Installation
Figure 21-13 Installed Tachometer Sensor
Page 21-23