14. OPTIONS AND AUXILIARY EQUIPMENT

14.1.5 External digital display (MR-DP60)

When using the MR-DP60, set " 0 2" in parameter No. 16.
(1) Specifications
Display
Power supply
Permissible voltage fluctuation
Current consumption
Communication
Interface
Baudrate
Bit length
Protocol
Communication commands
Operating temperature / humidity range
Storage temperature range
(2) Connection example
NFB
Power supply
200 to 230VAC
(3) Terminal arrangement
TB1
TXD TXD RXD RXD P5 LG
Note: The 5VDC output is designed for the internal control circuit and used to make a voltage check, etc. Do not use this terminal
to supply a voltage to the other equipment.
Item
Red seven-segment LED, signed, six digits
Single phase, 85 to 253VAC, 50/60Hz
Within 200mA
Conforms to RS-422A.
4800bps, asynchronous
Start bit 1, date bit 8, parity bit 1, stop bit 1
MELSERVO protocol
Commands dedicated to MELSERVO
0°C to 60°C, 90%RH or less, non-condensing
5°C to 70°C
L1
L2
L3
Servo amplifier
MR-J2-C
L11
L21
CN3
RDP
5
RDN
15
9
SDP
19
SDN
LG
1
Plate
SD
Signal
TB2
L1
RXD
L2
RXD
TXD
TXD
14 - 17
Specifications
Description
L1
100 to 230VAC power input
L2
Ground
Receive signal input
Inverse receive signal input
Inverse transmission signal output
Transmission signal output
P5
5VDC output (Note)
LG
Control common
External digital display
MR-DP60
L1
L2
TXD
TXD
RXD
RXD
LG

Hide quick links: