3. SIGNALS AND WIRING

3.7.2 Terminals

The positions and signal arrangements of the terminal blocks change with the capacity of the servo
amplifier. Refer to Section 12.2.1.
Symbol
L
, L
, L
Main circuit power supply
1
2
3
U, V, W
Servo motor output
L
, L
Control circuit power supply
11
21
P, C, D
Regenerative brake option
N
Protective earth (PE)
Signal
Main circuit power input terminals
Supply L
For a single-phase 230VAC power supply, connect the power supply to L1 and
L2 and keep L3 open:
Power supply
3-phase 200 to 230VAC,
50/60Hz
Single-phase 230VAC,
50/60Hz
Cannot be used for combination with the servo motor HC-SF52•53.
Servo motor power output terminals
Connect to the servo motor power supply terminals (U, V, W).
Control circuit power input terminals
Supply L
Regenerative brake option connection terminals
C and D are factory-connected.
When using the regenerative brake option, always remove wiring from across
P-D and connect the regenerative brake option across P-C.
Do not connect.
Ground terminal
Connect this terminal to the protective earth (PE) terminals of the servo
motor and control box for grounding.
Description
, L
and L
with the following power.
1
2
3
Servo amplifier
MR-J2-10C to 70C
and L
with single-phase 200-230VAC, 50/60Hz power.
11
21
3 - 22
MR-J2-100C to 350C
L
•L
•L
1
2
3
L
•L
1
2