1. FUNCTIONS AND CONFIGURATION

1.1.2 System configuration

This section describes operations using the MELSERVO-J2-C.
You can arrange any configurations from a single-axis to max. 32-axis systems. Further, the connector
pins in the interface section allow you to assign the optimum signals to respective systems. (Refer to
Sections 1.1.3 and 3.3.3.) The Set-up Software (refer to Chapter 6) and personal computer are required to
change or assign devices.
Set the following values to the point table:
Name
Position data
Motor speed
Acceleration time constant
Deceleration time constant
Dwell time
Auxiliary function
(1) Operation using external input signals
(a) Description
The following configuration example assumes that external input signals are used to control all
signals (devices).
The I/O signals are as factory-set.
(b) Configuration
The following configuration uses external I/O signals. The personal computer is used with the Set-
up Software to set, change and monitor the parameters and point tables.
Power supply
3-phase 200VAC
or single-phase
230VAC
Setting Range
999999 to 999999
0 to max. speed
0 to 20000
0 to 20000
0 to 20000
0 • 1
External I/O
signals
0: 1-point automatic operation
1: Automatic continuous operation
Servo amplifier
CN1A CN1B
RS–232C
CN2 CN3
Servo motor
1 - 3
Unit
0.001[mm]
0.01[mm]
0.1[mm]
1[mm]
[r/min]
[ms]
[ms]
[ms]
Personal
computer
Set-up
Software