8 – Language Dictionary
:PROTection
[:LEVel] <n>
:STATe <bool>
VOLTage2
[:LEVel]
[:IMMediate][:AMPLitude] <n>
:TRIGgered [:AMPLitude] <n>
STATus
:PRESet
:OPERation
[:EVENt]?
:CONDition?
:ENABle <n>
:NTRansition<n>
:PTRansition<n>
:QUEStionable
[:EVENt]?
:CONDition?
:ENABle <n>
:NTRansition<n>
:PTRansition<n>
SYSTem
:ERRor?
:LANGuage <language>
:VERSion?
TRIGger
:SEQuence2 | :ACQuire
[:IMMediate]
:COUNt
:CURRent <n>
:DVM <n>
:VOLTage <n>
:HYSTeresis
:CURRent <n>
:DVM <n>
:VOLTage <n>
:LEVel
:CURRent <n>
:DVM <n>
:VOLTage <n>
:SLOPe
:CURRent <slope>
:DVM <slope>
:VOLTage <slope>
:SOURce <source>
[:SEQuence1 | :TRANsient]
[:IMMediate]
:SOURce <source>
:SEQuence1
:DEFine TRANsient
:SEQuence2
:DEFine ACQuire
92
Table 8-1. Subsystem Commands Syntax (continued)
Sets the programmable output voltage limit
Enables/disables automatic overvoltage protection tracking
Sets the output2 voltage level
Sets the triggered output2 voltage level
Presets all enable and transition registers to power-on
Returns the value of the event register
Returns the value of the condition register
Enables specific bits in the Event register
Sets the Negative transition filter
Sets the Positive transition filter
Returns the value of the event register
Returns the value of the condition register
Enables specific bits in the Event register
Sets the Negative transition filter
Sets the Positive transition filter
Returns the error number and error string
Sets the programming language (SCPI)
Returns the SCPI version number
Triggers the measurement immediately
Sets the number of sweeps per current measurement
Sets the number of sweeps per DVM measurement
Sets the number of sweeps per voltage measurement
Qualifies the trigger when measuring current
Qualifies the trigger when making DVM measurements
Qualifies the trigger when measuring voltage
Sets the trigger level for measuring current
Sets the trigger level when making DVM measurements
Sets the trigger level for measuring voltage
Sets the triggered current slope (POS | NEG | EITH)
Sets the triggered DVM measurement slope (POS | NEG | EITH)
Sets the triggered voltage slope (POS | NEG | EITH)
Sets the trigger source (BUS | INT | TRIG)
Triggers the output immediately
Sets the trigger source (BUS)
Sets or queries the SEQ1 name
Sets or queries the SEQ2 name