7 - Programming the DC Source
Bit
Signal
0
CAL
5
WTG
8
CV
9
CV2
10
CC+
11
CC-
12
CC2
0
OV
1
OCP
3
FP
4
OT
5
OS
8
UNR2
9
RI
10
UNR
12
OC2
14
MeasOvld
0
OPC
2
QYE
3
DDE
4
EXE
5
CME
7
PON
3
QUES
4
MAV
5
ESB
6
MSS
RQS
7
OPER
Operation Status Group
The Operation Status registers record signals that occur during normal operation. As shown below, the
group consists of a Condition, PTR/NTR, Event, and Enable register. The outputs of the Operation Status
register group are logically-ORed into the OPERation summary bit (7) of the Status Byte register.
Register
Command
STAT:OPER:COND?
Condition
STAT:OPER:PTR <n>
PTR Filter
STAT:OPER:NTR <n>
NTR Filter
STAT:OPER:EVEN?
Event
STAT:OPER:ENAB <n>
Enable
84
Table 7-1. Bit Configurations of Status Registers
Meaning
Operation Status Group
The dc source is computing new calibration constants
The dc source is waiting for a trigger
The dc source is in constant voltage mode
Output 2 is operating in constant voltage mode
The dc source is in constant current mode
The dc source is in negative constant current mode
Output 2 is operating in constant current mode
Questionable Status Group
The overvoltage protection has tripped
The overcurrent protection has tripped
A front panel key has been depressed while in local mode
The overtemperature protection has tripped
An open sense lead has been detected
Output 2 is unregulated
The remote inhibit state is active
The output is unregulated
Output 2 overcurrent protection has tripped
Current measurement exceeded capability of low range
Standard Event Status Group
Operation complete
Query error
Device-dependent error
Execution error
Command error
Power-on
Status Byte and Service Request Enable Registers
Questionable status summary bit
Message Available summary bit
Event Status Summary bit
Master Status Summary bit
Request Service bit
Operation status summary bit
A register that holds real-time status of the circuits being monitored. It is a
read-only register.
A positive transition filter that functions as described under
STAT:OPER:NTR|PTR commands in chapter 8. It is a read/write register.
A negative transition filter that functions as described under
STAT:OPER:NTR|PTR commands in chapter 8. It is a read/write register.
A register that latches any condition that is passed through the PTR or NTR
filters. It is a read-only register that is cleared when read.
A register that functions as a mask for enabling specific bits from the Event
register. It is a read/write register.