Item
Noise
Calorific value
Power voltage
Frequency
Power consumption
External dimensions
Weight
Operation temperature and
humidity range
Standby temperature and
humidity range
Installation space
Maintenance space
Specification/Function
LP-1030
During operation (continuous sound):
During operation (discontinuous sound): 66 dB (A) or less
During standby:
5220 kJ or less
120V AC±10% (U.S.A version)
230V AC±10% (European version)
50 / 60 Hz ± 1 Hz
During operation: 1450 W or less
1200mm (47.24 inches) (W) ×
520mm (20.47 inches) (D) ×
1100mm (43.31 inches) (H)
185 kg (407.86 lb) or less
At the temperature 35˚C (95˚F), keep the humidity to 48% RH or
less.
At the humidity 80% RH, keep the temperature to 28˚C (82.4˚F) or
less.
-5 to 40°C (23 to 104˚F) / 10 to 90% RH or less (no condensation)
2100 mm (82.68 inches) (W) ×
1720 mm (67.72 inches) (D) ×
2000 mm (78.74 inches) (H)
3200 mm (125.98 inches) (W) ×
2320 mm (91.34 inches) (D) ×
2000 mm (78.74 inches) (H)
LP-1030/LP-1030-MF User's Manual for Basic Printer Operation
Basic Specifications
T
(2/2)
LP-1030-MF
61 dB (A) or less
53 dB (A) or less
1200mm (47.24 inches) (W) ×
605mm (23.82 inches) (D)×
1145mm (45.08 inches) (H)
205 kg (451.95 lb) or less
2100 mm (82.68 inches) (W) ×
1805 mm (71.06 inches) (D) ×
2000 mm (78.74 inches) (H)
3200 mm (125.98 inches) (W) ×
2405 mm (94.69 inches) (D) ×
2000 mm (78.74 inches) (H)
Chapter
1
Chapter
2
Chapter
3
Chapter
4
Chapter
5
215