Using the FTP Server Function
4-3-2

List of Settings Required for the FTP Server Function

4-3-3

Setup Tab

become effective. Verify that it is safe for the Ethernet Unit to restart before
transferring the settings data.
Make the following settings for the unit setup when the server function is used.
CX-Programmer
tab
Setup
The CPU Bus Unit System Setup, which is set when using the FTP server
function, is shown in the CX-Programmer's Unit Setup Window.
Settings
Setting
Login
Set the login name to externally connect to
the Ethernet Unit via FTP.
Password
Set the password to externally connect to the
Ethernet Unit via FTP.
Port No.
This setting does not normally need to be
changed.
FTP uses two ports: a port for control and a
port for data transfer. Set the control port
only. The data transfer port uses the value
set for the control port –1.
Settings
Setting conditions
Login
User-set (when the default, CON-
FIDENTIAL, is not used)
Password
User-set
Port No.
Rarely required (when the default,
21, is not used)
Details
Section 4-3
Page
71
Default value
None
(CONFIDENTIAL is
used.)
None
0
(21 is used.)
71