Auto Adjust Time - Omron CS CJ1W-ETN21 Operation Manual

Sysmac cs and cj series ethernet units construction of applications
Hide thumbs Also See for CS CJ1W-ETN21:
Table of Contents

Advertisement

Using the Automatic Clock Adjustment Function
5-2-3

Auto Adjust Time

The contents in the CPU Bus Unit System Setup that are set for using mail
send and receive functions are shown in the CX-Programmer's Unit Setup.
Item
Get the time
Enable to set the CPU Unit's clock to the time at the
information from
SNTP server's clock.
the SNTP
The clock can be changed only for the CPU Unit to
server
which the Ethernet Unit is mounted.
Auto Adjust
Set the time at which the SNTP server is to be
Time
accessed to synchronize the clocks.
When the time that is set here arrives, the SNTP
server is accessed and the CPU Unit clock is
adjusted to match the SNTP server clock.
Server specifi-
Select whether the SNTP server used for automatic
cation type
clock adjustment is to be specified by IP address or
by host domain name (i.e., by host name).
IP Address
Set the IP address for the SNTP server that is to be
used for automatic clock adjustment.
This setting is enabled only when server specification
by IP address has been selected.
Host name
Set the host domain name (i.e., the host name) for
the SNTP server that is to be used for automatic
clock adjustment.
This setting is enabled only when server specification
by host name has been selected.
Port No.
Set the port number for connecting to the SNTP
server that is to be used for automatic clock adjust-
ment. This setting does not normally need to be
changed.
Retry timer
Set the time to elapse before retrying when a connec-
tion to the SNTP server fails. This setting does not
normally need to be changed.
Adjust Time
This sets in the CPU Unit's clock data the time differ-
ence made up from the SNTP server's clock data.
To use the clock data from the SNTP server just as it
is, input 0.
Contents
Section 5-2
Default
Not
selected
(disabled)
0:0:0
IP Address
0.0.0.0
None
0
(Number
123 is
used.)
0
(10 s)
+0:0
93

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs cs1w-etn21Sysmac cs1w-etn21Sysmac cj1w-etn21