Using Socket Service Functions

6-5

Using Socket Service Functions

6-5-1

Procedure

1.
Make the basic settings.
Refer to SECTION 2 Startup Procedure in the Operation Manual Construction of Networks.
2.
Use the CX-Programmer or Programming Console to make the socket service settings in the
socket service parameter areas 1 to 8 (m+18 to m+88) allocated in the DM Area.
Note: The first word m in the allocated DM Area = D30000 + (100
3.
Select Transfer to PLC from the Options Menu, and then click the Yes Button. The Setup data
in the allocated DM Area will be transferred to the CPU Unit.
4.
Use one of the following methods to request socket services.
Manipulating Dedicated Control Bits
Turn each of the Socket Service Request Switches 1 to 8 in the CIO Area from OFF to ON.
Executing the CMND(490) Instruction
Send each of the socket service requests in FINS commands addressed to the Ethernet Unit.
6-5-2

Settings Required for Socket Service Function

The following settings must be made in the Unit Setup when using socket ser-
vices.
CX-Programmer
Unit Setup Tab
Setup
Broadcast
IP Address
Sub-net Mask
IP Router Table
TCP/IP keep-alive
×
unit number)
Setting
Setting requirements
Required.
Optional
Optional
Optional (Set when Ethernet
Unit will communicate through
the IP router with a socket on
another IP network segment)
Optional (Change when the
default setting of 120 min is
unacceptable.)
Section 6-5
Page
108
107