Example Application
3-9-3

Step 3. Transfer the CPU Bus Unit Setup Settings

3-9-4

Step 4. Send Remote Mail Commands

Reading Data from a
CPU Unit Data Area
Backing Up the CPU
Unit's User Program
in the Memory Card
66
Item name
Receive Command
Receive specified commands
Setting
only
FileWrite
FileRead
FileDelete
FileList
UMBackup
PARAMBackup
IOMWrite
IOMRead
ChangeMode
ErrorLogRead
ErrorLogClear
MailLogRead
MailLogClear
Test
FinsSend
Select Transfer to PLC from the Options Menu and click the Yes Button. The
settings will be transferred to the CPU Bus Unit Setup Area in the CPU Unit.
Send e-mails containing remote mail commands to the Ethernet Unit.
Example)
In this example, 10 words of data are read from words D00100 to D00109 and
converted to a file called D00100.CSV.
Subject: IOMRead
Body: Para1:38
Para2:D_100
Para3:10
Para4: D00100.CSV
Attached file: None
Example)
In this example, the CPU Unit's user program is backed up in a file called
USER.OBJ.
Subject: UMBackup
Body: Para2:USER.OBJ
Attached file: None
Section 3-9
Example
Selected
Not selected
Selected
Not selected
Selected
Selected
Selected
Not selected
Selected
Not selected
Selected
Selected
Selected
Selected
Selected
Not selected