Mail Send Function Specifications

2-3

Mail Send Function Specifications

2-3-1

Function Specifications

Item
Destination e-mail address
Subject
Body
Attached
Data format
file
Data size
Format
Number of
attachments
Mail triggers
Number of mail triggers
Contents of send mail condi-
tion settings 1 to 8
Sending method
(encoding)
Encryption
Compression
Protocols used
Mail send status
Up to 2 addresses can be registered in the Unit Setup (CPU Bus Unit System Setup) and
the addresses can be up to 50 characters long.
Fixed text (Depends on the trigger condition.)
User-set information (up to 1,024 bytes), the Ethernet Unit's error log, and the Ethernet
Unit's status information can be included individually or in any combination.
Any one of the following files can be selected in the Unit Setup (CPU Bus Unit System
Setup).
• I/O memory data
When the mail send condition is established, the data starting at the specified address in
the CPU Unit's I/O memory is automatically converted to a data file (.IOM, .TXT, or
.CSV) and sent as an attachment.
• File data
A Windows file with any filename extension
• I/O memory data: Up to 6,000 words (The max. size is the same for all file types.)
• File data: Up to 1 MB
MIME (version 1.0) format
Only 1 allowed
The mail triggers can be selected in the Unit Setup (CPU Bus Unit System Setup).
1. OFF to ON transition of a dedicated control bit (the Mail Send Switch)
2. Change in the value of a specified word (=, <>, <, <=, >=, or >)
3. Change in the status of a specified bit (OFF-to-ON or ON-to-OFF transition)
4. Change in the Ethernet Unit (event entered into the error log)
5. Change in the CPU Unit (non-fatal error occurred, fatal error occurred, or operating
mode changed)
6. Periodic timer
Note Set the monitoring interval when using triggers 2 and 3. Set the sending interval
when using trigger 6.
Up to 8 triggers can be set and operated simultaneously.
Make the following settings in the Unit Setup (CPU Bus Unit System Setup):
• E-mail body information (user-set information, error log, and status information)
• Attached file type (any file in file memory or data file with filename extension .IOM, .TXT,
or .CSV), attached file name
• Mail trigger type (set trigger types listed above for triggers 1 to 8, trigger data address,
and word comparison set value)
• Starting address of user-set information
• Starting address of attached I/O memory data and number of words
• Time interval (Set for mail trigger 2 change in value of specified word, mail trigger 3
change in status of specified bit, or mail trigger 6 periodic timer)
Subject:
Us ASCII
Body:
Us ASCII (Information types 2 through 4 can be sent in the body.)
Attached file: Base64
None
None
SMTP (port number 25: can be changed with the CX-Programmer Unit Setup)
(The POP before SMTP method can also be set.)
Transmission status information such as mail being sent, normal completion, and error
completion is indicated for each of the 8 send mail condition settings in words m (Mail Sta-
tus 1) and m+17 (Mail Status 2) in the DM Area words allocated to the Ethernet Unit as a
CPU Bus Unit.
Specifications