Startup/Shutdown Of Web Maintenance Mode - Konica Minolta DRYPRO Model 793 Operation Manual

Table of Contents

Advertisement

Ch.5 Web Maintenance Mode

5-2 Startup/Shutdown of Web Maintenance Mode

How to start up or shut down the Web Maintenance Mode is detailed below.
5-2-1 Startup of the Web Maintenance Mode (Menu Mode)
How to start up the Web Maintenance Mode (Menu Mode) is detailed below.
Prepare a PC that should be used for Web Maintenance.
Web Maintenance Mode can be started while the DRYPRO 793 is in warming up
sequence. However, the Web Maintenance Mode cannot be operated in the meantime.
DRYPRO Vstage MODEL 793 Operation Manual Ver.1.01 2005.1
1
Start up the PC for the Web Maintenance.
2
Connect the Ether cable to the PC.
3
Start up the DRYPRO 793.
4
Connect the other end of the Ethernet cable that is
connected to the PC in the step 2, to the hub to
which the DRYPRO 793 is connected.
5
Start up the Internet Explore on the PC that is
used for the Web Maintenance.
- A message "Cannot open the page" will appear.
6
Input the IP address of the DRYPRO 793 following
"http://".
- "MENU MODE" screen of the Web Maintenance Mode will
be displayed.
< 103 >
DRYPRO 793 and the
PC can be interfaced
with a cross cable
instead of using a hub.