4. TROUBLESHOOTING

4.1 PROCESS CONTROL ERROR CONDITIONS
4.1.1 DEVELOPER INITIALIZATION RESULT
SP-3-005-006 (Developer Initialization Result)
No.
Result
Description
Not
Developer
performed
initialization is not
performed.
0
Successfully
Developer
completed
initialization is
1
successfully
completed.
Forced
Developer
termination
initialization was
forcibly terminated.
2
Vt error
Vt is less than 0.5V
and "Reset
development unit"
is displayed.
3
SM
PROCESS CONTROL ERROR CONDITIONS
Possible Causes
When initializing only
the black developer, the
initialization result
becomes "1000".
A cover was opened or
the main switch was
turned off during the
initialization.
1. Check if the drum stay is correctly set and secured.
2. Check if the development unit is correctly set.
3. Check the following if the problem stays:
• Poor connection of connectors
• TD sensor defective
• Harness damage
• BCU board failure
• Firmware problem (engine main or MUSIC)
4-1
Action
When done in SP mode, do
the developer initialization
again. Reinstall the engine
main firmware if the result is
the same.
Do the following when done at
unit replacement:
• Check if a new unit is
installed
• Check if the unit detection
system works correctly
• Check if SP2-223-001 (auto
initialization at unit
replacement) is enabled.
-
When done in SP mode, do
the developer initialization
again. Reinstall the engine
main firmware if the result is
the same.
Turn the main switch off and
on when done at unit
replacement.