5.8.2 DETAILED SELF-DIAGNOSTICS

In addition to the self-diagnostic test initiated every time the main machine is
powered on, you can set the machine in a more detailed diagnostic mode manually.
This lets you test other components or conditions that are not tested during self-
diagnosis after power on. The following device is required in order to put the
machine in the detailed self-diagnosis mode:
No.
G0219350
Parallel Loopback Connector
Executing Detailed Self-Diagnosis
Do the following procedure to execute detailed self-diagnosis.
1. Switch off the machine, and connect the parallel loopback device to the
Centronics I/F port.
2. Hold down , press and hold down . Then switch on the machine while
pressing both keys at the same time.
You will see "Now Loading" on the touch-panel. Then you will see the results of
the test.
The machine automatically starts the self-diagnostics and prints the diagnostic
report after completing the test.
• Refer to the diagnostics report for the detected errors. You can check the
errors detected during self-diagnostics with SP7-832-001 (Diag. Result).
• Refer to section 4.3 for details about the error codes.
SM
Name
5-165
CONTROLLER SELF-DIAGNOSTICS
B202/B178/B180