Hearth Requirements – Recessed Hearth
A hearth is not required if raised 6" above the flooring surface.
NOTE: Make sure to accommodate the flooring surface - this
distance must be measured from the top of carpeting or other
flooring material.
WARNING:
We recommend a hearth to protect the flooring
surface from discoloration or other negative
impact from the heater, especially if it is near the
minimum raised height.
Side View
Minimum 6" to top of
flooring surface
(carpet, etc.)
Carpet
© Travis Industries
Installation
(for qualified installers only)
Min. 6"
Fireplace
1-1/2"
Plywood (OSB, etc.)
Framing
Sub-Floor
Cement Board
NOTE: When building a raised fireplace, consider the facing
material below the fireplace. If using tile, you may wish to
make the platform a suitable height for un-cut tile. For
example, if using 12" tile, make the platform 10-1/2" tall (10"
section of framing + 1/2" plywood).
4090807
35
Figure 24