Fireplace Placement Requirements
•
The fireplace requires a 4" clearance from the sides and 2" from the back of the fireplace to the
framing members. No material (insulation, framing, etc.) may be placed into this area.
•
Fireplace must be placed in a room with a minimum 96" ceiling.
•
Fireplace must be placed directly on the sub-floor or wood platform (not on linoleum or carpet).
•
Fireplace must be installed on a level surface capable of supporting the fireplace and vent.
•
This heater may be placed in a bedroom. Please be aware of the large amount of heat this
appliance produces when determining a location.
Clearances
•
When installed, walls in front of the fireplace must be a minimum 11" from the glass (5" from
the side stand-offs - see Figure 3).
•
Due to the high temperature, the heater should be located out of traffic and away from furniture
and draperies.
•
Fireplace must be placed so the vents below and above the glass do not become blocked.
Raised Fireplaces
•
The fireplace (and hearth, if desired) may be placed on a platform designed to support the
fireplace 250 Lbs.) and vent.
Minimum 60" Fireplace
Enclosure must also
meet 6" vent clearance.
(see "Hearth Requirements" for details)