Travis Industries 1080 CF Installation Manual page 53

Hide thumbs Also See for 1080 CF:
Table of Contents

Advertisement

Finalizing the Installation
5
Follow the directions below to replace the orifice.
a
Use a 1/2" open end wrench
to unscrew the orifice.
Manifold
c
Screw each LP orifice in so the
orifice protrudes 15/16"
(indicating full insertion).
© Travis Industries
Burner Orifice
1/2" Wrench
Burner Orifice
(for qualified installers only)
Apply thread sealant to the LP
orifices prior to installation. Use
the chart below to identify the
correct orifices.
Look here for the orifice identification
15/16"
4090807
b
NG
LP
#33
#50
100-01193_003