Installation (for qualified installers only)

Fireplace Requirements

Insert must be placed within a code-conforming masonry fireplace or tested and listed factory-built
(metal) wood-burning fireplace. Repair any fireplace damage prior to installation.
Because the insert uses a circulation blower, clean the fireplace, smoke shelf, and chimney prior to
installation.
This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance
produces when determining a location.
Do not place insulation or any other material on top of the insert. This may block the upper accent
light ventilation, leading to premature bulb failure.
The fireplace and fireplace chimney must be clean and in good working order and constructed of non-
combustible materials.
The chimney cleanouts must fit properly
Trim panels or surrounds shall not seal ventilation openings in the fireplace
I
Attach the "This fireplace has been altered..." plate to the fireplace (use two screws or other suitable
method). You may wish to place it in a location where it will be covered by the surround panels.
Fireplace Clearances to Gas Insert
Side of Insert to Inside of Fireplace
Back of Insert to Inside of Fireplace
Top of Insert to Inside of Fireplace

Masonry Fireplace Hearth Requirements

A panel trim kit is available for this appliance. When using the kit, the appliance will sit forward of the fireplace
opening 1-1/4" (32mm).
WARNING: A non-combustible hearth is not required in front of the appliance. However, if the heater is installed
next to the floor, we recommend a hearth to protect the flooring surface from discoloration or other
negative impacts from the heater.
© Travis Industries
Fireplace Sizing
a
Minimum Height
b
Minimum Width
c
Minimum Depth
d
Hearth Depth
(see "Hearth
Requirements" on
the following page
for full details)
e
Hearth
Extension
The gas and electrical line should be installed prior to installing
f
the heater.
g
For tight fits (under 28") see the section "Removing the Vent
Connector"
h
See "Leveling Legs" for details on leveling the heater.
1/2" (13mm)
1/2" (13mm)
5/8" (18mm)
1/10/2022 - 1559
1-Piece Panel
1-Piece Panel w/ trim
24" (610mm)
23-1/2" (597mm)
35" (889mm)
34-5/8" (880mm)
16-1/2" (420mm)
15-1/4" (387mm)
0" (0mm)
0" (0mm)
1-1/4" (32mm)
0" (0mm)
616 MF GSR2