SAFETY NOTICE:
If this appliance is not properly installed, a house fire may
result. For your safety, follow the installation directions.
Contact local building or fire officials about restrictions and
installation inspection requirements in your area.
Travis Industries, Inc.
4800 Harbour Pointe Blvd. SW
Mukilteo, WA 98275
www.travisproducts.com
Owner's Manual
Save these instructions
for future reference
 Copyright 2009, T.I.
$10.00
100-01233_000
4090819
Zero-Clearance (Metal)
Fireplace Insert
U.L. 1482 and ULC S628-M93
Tested to:

Advertisement

Table of Contents
loading

Summary of Contents for Travis Industries 1250 Insert

  • Page 1 If this appliance is not properly installed, a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. Travis Industries, Inc.  Copyright 2009, T.I. 4800 Harbour Pointe Blvd. SW $10.00...
  • Page 2: Introduction

    Introduction Introduction We welcome you as a new owner of a 1250 wood-burning fireplace insert. In purchasing a 1250 you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics. The 1250 is one of the finest appliances the world over.
  • Page 3: Table Of Contents

    Adjusting the Burn Rate ........17 Ash Removal ............ 17 Optional Blower Operation........18 Re-Loading the Stove ......... 18 Overnight Burn..........18 Normal Operating Sounds ........18 Hints for Burning..........19 Selecting Wood ..........19 Troubleshooting ..........20 © Travis Industries 100-01233_000 4090819...
  • Page 4: Safety Precautions

    (UL 103 HT) Clay cause a house fire. residential type chimney or an Liner Do not connect this appliance to approved masonry chimney with any chimney serving another a standard clay tile, or stainless appliance. steel liner. © Travis Industries 100-01233_000 4090819...
  • Page 5 Avoid placing wood against the glass when loading. Do not slam the door or strike the glass. Do not throw this manual away. Travis Industries, Inc. grants This manual has important no warranty, implied or This operating and maintenance...
  • Page 6: Features & Specifications

    It is also affected by the quality and moisture level of the fuel. Dimensions: Note: Measure side, corner, and back clearances from the stove top. 5-7/8" 23-5/8" 20" 18-5/8" 13-1/2" 3" Figure 1 Emissions: 4.4 Grams Per Hour (EPA Phase II Approved) – Tests conducted by E.E.S.P.C. © Travis Industries 100-01233_000 4090819...
  • Page 8: Fireplace Requirements

    16" ** (** 18" in Canada) Hearth (Side) 8" 8" Front of Insert 36" 36" Extension onto Hearth 3" 3" * Does not include the distance the insert extends onto the hearth (dimension "x"). Figure 3 © Travis Industries 100-01233_000 4090819...
  • Page 10: Hearth Requirements

    This appliance relies upon natural draft to operate. External forces, such as wind, barometric pressure, topography, or factors of the home (negative pressure from exhaust fans, chimneys, air infiltration, etc.), may adversely affect draft. Travis Industries can not be responsible for external forces leading to less than optimal performance. Leveling Bolt Installation Two leveling bolts are included to level the insert if the fireplace has a stepped-up hearth.
  • Page 11: Block-Off Plate Installation

    Measurement "C" See the dimensions to determine the location of the Measurement "B" center of the Firebox flue. See the dimensions to determine the location of the center of the flue. Figure 6 © Travis Industries 100-01233_000 4090819...
  • Page 12: Insert With Positive Connection

    (see "Block-off See the section Plate Installation" on "Insert Placement page 11). Requirements" for Block-off plate or minimum clearances damper adapter and hearth required. © Travis Industries 100-01233_000 4090819...
  • Page 13: Insert With Direct Connection (Z.c. Fireplace)

    Panels" installation instructions in the back of "Surround Panel the manual) Installation" on page 31). Airtight Insulated Clean-Out See the section "Insert Placement Requirements" for minimum clearances and hearth required. Remove damper or wire it open © Travis Industries 100-01233_000 4090819...
  • Page 15: Operating Your Appliance

    The door becomes hot during use. Use a glove to open the door if the handle is hot. To prevent smoke from entering the room, open the door a small amount and let air enter the firebox. Lopi Republic Door Rotate Swing the door the door handle. open. © Travis Industries 100-01233_000 4090819...
  • Page 16: Starting A Fire

    When you light the newspaper this “top-down” fire will burn its way to the center, igniting the larger pieces. With some practice, this method should work for you. © Travis Industries 100-01233_000 4090819...
  • Page 17: Adjusting The Burn Rate

    If the ashes are disposed of by burial in soil or otherwise locally ASHES dispersed, they should be retained in the closed container until all cinders have thoroughly cooled. © Travis Industries 100-01233_000 4090819...
  • Page 18: Optional Blower Operation

    The 3/16" and 5/16" steel may creak or click when the stove heats up and cools down - this is normal. Blower Sounds: The blower will make a slight "humm" as it pushes air through the stove. © Travis Industries 100-01233_000 4090819...
  • Page 19: Hints For Burning

    Wood Cutting and Storage Cut wood to length and Store the wood off the ground in a chop into quarters. covered area. Allow for airflow Air Flow around the wood to dry the wood. Air Flow Air Flow © Travis Industries 100-01233_000 4090819...
  • Page 20: Troubleshooting

    See the section "Door and Glass Inspection" on page 22 for details. • Check the ash bed for coals. Often, coals are still glowing under a slight bed of flyash. By raking these into a pile you can re-start your stove quickly. © Travis Industries 100-01233_000 4090819...
  • Page 21: Maintaining Your Appliance

    The ash acts as a light abrasive. The glass will develop a very slight haze over time. This is normal and will not affect viewing of the fire. © Travis Industries 100-01233_000 4090819...
  • Page 23: Yearly Maintenance

    Slight scaling or rusting of the metal is normal. Make sure the pins hold the air tubes in place. Floor and Wall Firebricks - replace any severely damaged firebrick along the side or floor of the firebox. © Travis Industries 100-01233_000 4090819...
  • Page 25: Firebox Parts

    Do not pry firebrick - they chip and crack easily. Remove the floor firebricks first. The side firebricks are removed later because they are pinned in place by the floor firebrick. Clean the firebox prior to replacing the firebrick. © Travis Industries 100-01233_000 4090819...
  • Page 26: Baffle Removal & Replacement

    All three air tubes are identical. Air Tube Collar Air Tube Remove the left pin on the air tube collar Roll Pin Slide the air tube to the left, swing it down and remove from the firebox. © Travis Industries 100-01233_000 4090819...
  • Page 27: Warranty Warranty

    Limited 5 Year Warranty To register your TRAVIS INDUSTRIES, INC. 5 Year Warranty, complete the enclosed warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd. SW, Mukilteo, WA 98275. TRAVIS INDUSTRIES, INC. warrants this appliance (appliance is defined as the equipment manufactured by Travis Industries, Inc.) to be defect-free in material and workmanship to the original...
  • Page 28: If Warranty Service Is Needed

    21. This 5 year warranty is the only warranty supplied by Travis Industries, Inc., the manufacturer of the appliance. All other warranties, whether express or implied, are hereby expressly disclaimed and purchaser’s recourse is expressly limited to the warranties set forth herein.
  • Page 29: Listing Information

    Listing Information Listing Label © Travis Industries 100-01233_000 4090819...
  • Page 30: Optional Equipment Surround Panels

    2. Adjust the position of the side panels so they are: 1) flush with the bottom of the insert; 2) both the same distance back from the front of the insert; 3) perpendicular to the floor (use the top panel, if necessary, to judge alignment). Tighten the screws that hold the side panels in place. © Travis Industries 100-01233_000 4090819...
  • Page 31 2. Push the insert into the fireplace, allowing the insulation to form a seal between the panels and the fireplace. Use a screwdriver to tuck any exposed insulation behind the panels. © Travis Industries 100-01233_000 4090819...
  • Page 32: Front Blower (Part # 99000128)

    Control Box Use a 3/8" nutdriver to replace the two screws that hold the front blower to the appliance. 2. Plug the power cord running from the control box into a grounded 110 volt electrical outlet. © Travis Industries 100-01233_000 4090819...
  • Page 33 Optional Equipment © Travis Industries 100-01233_000 4090819...
  • Page 34: Index

    Glass Replacement ........24 Hearth (Floor Protection).........8 Heating Specifications ........6 Hints for Burning ...........19 Installation (planning) ........7 Installation Options ........6 Installation ...........7 Listing Label..........29 Maintenance ..........21 Masonry Fireplace .........9 Monthly Maintenance ........22 Noise (Normal Operating Sounds) ....18 © Travis Industries 100-01233_000 4090819...