Document Does Not Feed Or Multiple Feeds - Toshiba E-STUDIO190F Service Manual

Plain paper facsimile
Hide thumbs Also See for E-STUDIO190F:
Table of Contents

Advertisement

4.4.2.

Document Does Not Feed or Multiple Feeds

START
Is the ADF Unit closed?
Is the adjustment of the
Separator Pad normal?
Is the ADF Roller clean?
Is the ADF Roller worn out?
Does the ADF Roller drive
properly?
END
No
Yes
No
Yes
Is the Separator Pad worn
out?
Replace the Separator Pad.
No
Yes
Clean the surface of the roller
with water (Sect. 2.).
Yes
Replace the ADF Roller
No
(Sect. 2.).
No
Yes
Does the ADF Roller's gear
system function properly?
Close the ADF Unit firmly.
Yes
Yes
100
No
Clean or adjust the Separator
Pad Pressure (Sect. 2.).
No
Adjust the gear system or replace
defective parts.

Advertisement

Table of Contents
loading

Table of Contents