No.
Parameter
011 RX Level
012 DTMF Level
013 G3 RX EQL
014 G3 TX EQL
015 ~
Not Used
016
017 TX Start
018 RX Start
019 ITU-T V.34
020 ITU-T ECM
021 EP Tone
022 Signal Interval
023 TCF Check
024 CED Frequency
Function Parameter Table
Selections
1 = -43 dBm
2 = -38 dBm
3 = -33 dBm
4 = -48 dBm
00 = 0 dBm
~
15 = -15 dBm
1 = 0dB
2 = 4dB
3 = 8dB
4 = 12dB
1 = 0dB
2 = 4dB
3 = 8dB
4 = 12dB
2400 bps
4800 bps
7200 bps
9600 bps
TC7200
TC9600
12000 bps
14400 bps
2400 bps
4800 bps
7200 bps
9600 bps
TC7200
TC9600
12000 bps
14400 bps
1 = Off
2 = On
3 = Select
1 = Off (Invalid)
2 = On (Valid)
1 = Off (without EP Tone)
2 = On (with EP Tone)
1 = 100 ms
2 = 200 ms
3 = 500 ms
1 = Normal (Short)
2 = Long
1 = 1080 Hz (non ITU-T)
2 = 2100 Hz
Selects the receiving sensitivity of -33/-38/-43/-48
dBm.
Selects the DTMF output level, 0 to -15 dBm in 1
dBm steps.
Selects the cable equalizer for G3 reception mode,
0dB, 4dB, 8dB or 12dB.
Selects the cable equalizer for G3 transmission
mode, 0dB, 4dB, 8dB or 12dB.
Selects the transmission modem start speed,
14400/12000/TC9600/TC7200/9600/7200/4800/
2400 bps.
(Press "V" or "/\ " to select the symbol rate.)
Note:
This parameter is applicable only when
communicating with regular G3 machines. When
communicating with Super G3 (V.34) machines,
use Parameter No. 32.
Selects the reception modem start speed, 14400/
12000/TC9600/TC7200/9600/7200/4800/2400 bps.
(Press "V" or "/\ " to select the symbol rate.)
Note:
This parameter is applicable only when
communicating with regular G3 machines. When
communicating with Super G3 (V.34) machines,
use Parameter No. 33.
Selects whether the ITU-T V.34 is Off, On or Select.
Select: Select whether the ITU-T V.34 is Off or On,
when entering Phone Book Dialing
Numbers or Manual Number Dialing.
Select the ECM mode.
Selects whether to add the echo protect tone on
V.29 mode.
(Used when Echo Suppression is disabled.)
On : Add
Off : Do not add
Selects the time interval between the receiving
signal and the transmitting signal.
Selects the TCF check interval Long/Short
Selects the CED frequency 2100/1080 Hz