Chapter 15: Storage management
6. Type in a name for the array, select the RAID Level, Initialization Type, and the
drives to be included.
7. Click
OK
and then
data on the RAID group is displayed.
Note: You can create a RAID array of RAID 0, RAID 1, RAID 5, and RAID 10.
If you choose RAID 0, at least 2 HDDs must be installed.
If you choose RAID 1, 2 HDDs need to be configured for RAID 1.
If you choose RAID 5, at least 3 HDDs must be installed.
If you choose RAID 10, 4/6/8 HDDs need to be configured for RAID 10.
To verify the RAID go to click
To rebuild a damaged RAID:
If a drive in the RAID array fails you can rebuild the array.
112
Initialize
to start the process. When the process is complete,
Storage Management
>
HDD Information.