4. EXTCTR signal (output signal)
The EXTCTR signal is synchronized with "Exit sensor ON" and becomes "Low" (ON) for 200 ms.
The coin controller counts the number of times with this signal.
This is the signal only for the coin controller.
<PIS-EXIT: Paper exit sensor>
With paper
Without paper
<EXTCTR>
5. LARGE/SMALL signal (output signal)
When large size paper (A3 / A3 wide / LD) is selected or paper size is not specified with the manual
feeding, it outputs "Low" in real time. In other cases, it outputs "High". The setting change for large
size paper is performed with F/W.
This is the signal only for the coin controller.
6. FULL COLOR signal (output signal)
If the full color mode is selected, it outputs "Low" in real time. In other cases, it outputs "High". By
default, it outputs "Low" since it is set as full color mode.
This is the signal only for the coin controller.
7. TWN / MON COLOR signal (output signal)
If the twin color or mono color mode is selected, it outputs "Low" in real time. In other cases, it
outputs "High". This is the signal only for the coin controller.
8. B/W signal (output signal)
If the black mode is selected, it outputs "Low" in real time. In other cases, it outputs "High". This is
the signal only for the coin controller.
e-STUDIO2330C/2820C/2830C/3520C/3530C/4520C
EXTERNAL COUNTERS
(Paper length / Feeding speed)
OFF
ON
Fig. 29-3
29 - 4
200ms
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved