Laser Optical Unit Related Service Call - Toshiba e-STUDIO2330C Service Manual

Hide thumbs Also See for e-STUDIO2330C:
Table of Contents

Advertisement

26.3.18 Laser optical unit related service call

[CA10] Polygonal motor abnormality
Is the polygonal motor rotating?
NO 
|
<e-STUDIO2330C//2820C/2830C/3520C/3530C>
|
1. Check if the connector of the polygonal motor is disconnected.
|
2. Check if the relay connector J506 is disconnected.
|
3. Check if the connector CN343 on the LGC board is disconnected.
|
4. Check if the conductor pattern on the LGC board is short circuited or open
|
|
5. Replace the LGC board.
|
6. Replace the laser optical unit.
|
<e-STUDIO4520C>
|
1. Check if the connector on the POL board is disconnected.
|
2. Check if the connectors on the both edges of the HRNS-POL-DRV-382 are
|
|
|
3. Check if the relay connector J506 is disconnected.
|
4. Check if the connector CN343 on the LGC board is disconnected.
|
5. Check if the conductor pattern on the POL board is short circuited or open
|
|
6. Replace the POL board.
|
7. Check if the conductor pattern on the LGC board is short circuited or open
|
|
8. Replace the LGC board.
|
9. Replace the laser optical unit.
|
YES
Is the printed image distorted?
YES  <e-STUDIO2330C//2820C/2830C/3520C/3530C>
|
1. Check if the connector CN343 on the LGC board is almost disconnected.
|
|
2. Check if the relay connector J506 is almost disconnected.
|
3. Check if the harness is almost open circuited or the connector pin is almost
|
|
4. Check if the conductor pattern on the LGC board is short circuited or open
|
|
5. Check if the laser unit cooling fan is stopped.
|
6. Check if the suction area of the laser unit cooling fan is plugged up.
|
7. Replace the laser optical unit.
|
8. Replace the LGC board.
|
<e-STUDIO4520C>
|
1. Check if the connector CN343 on the LGC board is almost disconnected.
|
|
2. Check if the relay connector J506 is almost disconnected.
|
3. Check if the connectors on the both edges of the HRNS-POL-DRV-382 are
|
|
4. Check if the harness is almost open circuited or the connector pin is almost
|
|
5. Check if the conductor pattern on the POL board is short circuited or open
|
|
6. Check if the conductor pattern on the LGC board is short circuited or open
|
|
7. Check if the laser unit cooling fan is stopped.
|
8. Check if the suction area of the laser unit cooling fan is plugged up.
|
|
9. Replace the laser optical unit.
10.Replace the LGC board.
NO
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
circuited.
disconnected.
circuited.
circuited.
disconnected.
circuited.
almost disconnected.
disconnected.
circuited.
circuited.
26 - 67