(10) Measure the distance (L) between the stitching position and the folding position. Then perform
"positive width adjustment" or "negative width adjustment" to suit the relationship between the
stitching position and the folding position.
If the stitching position is below the folding position, perform "positive width adjustment."
If the stitching position is above the folding position, perform "negative width adjustment."
Positive Width Adjustment
Unit: mm
Example: If L is 1 mm, provide "+1 mm".
(11) Change the settings of bits 6 through 8 on SW504 referring to the following table.
If the width adjustment is 0
The stitching position and the folding position match, requiring no change.
If for "positive width adjustment"
Set SW504 so that the difference resulting from subtraction of the interval from the
appropriate setting in the table below is provided.
Example: If SW504 is currently set to +2 and the interval is +1 mm, set SW504 to reflect - 2.
If for "negative width adjustment"
Set SW504 so that the sum resulting from addition of the interval from the appropriate setting
in the table below is provided.
Example: If SW504 is currently set to -1 and the interval is -0.5mm, set SW504 to reflect +1.
DIPSW1 bit settings
Bit 6
OFF
OFF
OFF
OFF
ON
ON
ON
(12) Set SW504 bits 1 to 4 to OFF.
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
Mark
Folding position
Stitching position
Fig. 28-78
Bit 7
Bit 8
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
Do not use the following setting
Bit 6
Bit 7
ON
OFF
28 - 35
Negative Width Adjustment
Unit: mm
Example: If L is 0.5 mm, provide "-0.5 mm".
Setting
(in units of 0.5 mm)
+3
+2
+1
0
-1
-2
-3
Bit 8
OFF
e-STUDIO2330C/2820C/2830C/3520C/3530C/4520C
SETTING / ADJUSTMENT OF OPTION
Mark
Stitching position
Folding position
28