Manuals and User Guides for wtw Oxi 3315. We have
2
wtw Oxi 3315 manuals available for free PDF download: Operating Manual
wtw Oxi 3315 Operating Manual (60 pages)
Digital meter for digital IDS dissolved oxygen sensors
Brand:
wtw
| Category:
Measuring Instruments
| Size: 0.73 MB
Table of Contents
Table of Contents
3
Contents Oxi
6
1 Overview
7
Oxi 3315 Meter
7
Sensors
7
IDS Sensors
8
Automatic Sensor Recognition
8
2 Safety
9
Safety Information
9
Safety Information in the Operating Manual
9
Safety Signs on the Meter
9
Further Documents Providing Safety Information
9
Safe Operation
10
Authorized Use
10
Requirements for Safe Operation
10
Unauthorized Use
10
3 Commissioning
11
Scope of Delivery
11
Power Supply
11
Initial Commissioning
11
Inserting the Batteries
12
4 Operation
14
General Operating Principles
14
Keypad
14
Display
15
Status Information (Meter)
15
Socket Field
16
Sensor Info
16
Switching on the Meter
17
Switching off the Meter
17
Navigation
18
Operating Modes
18
Measured Value Display
18
Menus and Dialogs
18
Example 1 on Navigation: Setting the Language
20
Example 2 on Navigation: Setting the Date and Time
22
5 Dissolved Oxygen
24
Measuring
24
Measuring D.O
24
Measuring the Temperature
26
FDO ® Check Procedure
26
Why Should You Check the Sensor
26
When Should You Check the Sensor
26
Carrying out the FDO
26
Evaluation
27
Calibration
28
Why Calibrate
28
When to Calibrate
28
Calibration Procedures
28
Calibration in Water Vapor-Saturated Air
29
Calibration by Means of a Comparison Meas
29
(FDO Comp)
29
Calibration Data
31
6 Settings
33
Measurement Settings
33
Settings for D.O. Sensors (Menu or Measurement and Calibration Settings)
33
Sensor-Independent Settings
34
System
34
Data Storage
35
Automatic Stability Control
35
Automatic Switch-Off
36
Display Illumination
36
Reset
36
Resetting the Measurement Settings
36
Resetting the System Settings
37
7 Data Storage
38
Manual Storage
38
Automatic Storage at Intervals
39
Measurement Data Storage
41
Editing the Measurement Data Storage
41
Erasing the Measurement Data Storage
42
Measurement Dataset
43
Storage Locations
43
8 Transmitting Data (USB Interfaces)
44
Outputting Current Measurement Data
44
Transmitting Data (to a PC)
44
Connecting the PC / USB-B Interface (USB Device)
44
Options for Data Transmission to a PC
45
Multilab Importer
45
9 Maintenance, Cleaning, Disposal
46
Maintenance
46
General Maintenance Activities
46
Replacing the Batteries
46
Cleaning
47
Packing
47
Disposal
47
10 What to Do if
48
Dissolved Oxygen
48
General Information
48
11 Technical Data
50
Measuring Ranges, Resolution, Accuracy
50
General Data
50
12 Firmware Update
52
Firmware Update for the Meter Oxi 3315
52
Firmware-Update for IDS Sensors
53
13 Glossary
54
14 Index
57
Advertisement
wtw Oxi 3315 Operating Manual (60 pages)
DIGITAL METER FOR DIGITAL IDS-D.O. SENSORS
Brand:
wtw
| Category:
Measuring Instruments
| Size: 0.67 MB
Table of Contents
Table of Contents
3
1 Overview
7
Oxi 3310 IDS (Oxi 3315) Meter
7
Sensors
7
IDS Sensors
8
Automatic Sensor Recognition
8
2 Safety
10
Safety Information
10
Safety Information in the Operating Manual
10
Safety Signs on the Meter
10
Further Documents Providing Safety Information
10
Safe Operation
11
Authorized Use
11
Requirements for Safe Operation
11
Unauthorized Use
11
3 Commissioning
12
Scope of Delivery
12
Power Supply
12
Initial Commissioning
12
Inserting the Batteries
13
4 Operation
14
General Operating Principles
14
Keypad
14
Display
15
Status Information (Meter)
15
Connectors
16
Sensor Info
16
Switching on the Meter
17
Switching off the Meter
17
Navigation
18
Operating Modes
18
Measured Value Display
18
Menus and Dialogs
18
Navigation Example 1:Setting the Language
20
Example 2 on Navigation: Setting the Date and Time
22
5 Dissolved Oxygen
24
Measuring
24
Measuring D.O
24
Measuring the Temperature
26
FDO ® Check Procedure
26
Why Should You Check the Sensor
26
When Should You Check the Sensor
26
Carrying out the FDO ® Check Procedure
27
Evaluation
28
Calibration
28
Why Calibrate
28
When to Calibrate
28
Calibration Procedures
28
Calibration in Water Vapor-Saturated Air
29
Calibration with Comparison Meas. (FDO Comp)
30
Calibration Data
31
6 Settings
33
Measurement Settings
33
Settings for D.O. Sensors (Menu for Measurement and Calibration Settings)
33
Sensor-Independent Settings
34
System
34
Data Storage
35
Automatic Stability Control
35
Automatic Switch-Off Function
36
Display Illumination
36
Reset
37
Resetting the Measurement Settings
37
Resetting the System Settings
37
7 Data Memory
39
Manual Storage
39
Automatic Data Storage at Intervals
40
Measurement Data Memory
42
Editing the Measurement Data Memory
42
Erasing the Measurement Data Memory
43
Measurement Dataset
44
Storage Locations
44
8 Transmitting Data (USB Interface)
45
Outputting Current Measurement Data
45
Transmitting Data (to a PC)
45
Connecting the PC / USB-B Interface (USB Device)
45
Options for Data Storage to a PC
46
Multilab Importer
46
9 Maintenance, Cleaning, Disposal
47
Maintenance
47
General Maintenance Activities
47
Replacing the Batteries
47
Cleaning
48
Packing
48
Disposal
48
10 What to Do if
49
Dissolved Oxygen
49
General Information
49
11 Technical Data
51
Measuring Ranges, Resolution, Accuracy
51
General Data
51
12 Firmware Update
53
Firmware Update for the Meter Oxi 3310 IDS (Oxi 3315)
53
Firmware-Update for IDS Sensors
54
13 Glossary
55
14 Index
57
Advertisement
Related Products
wtw Oxi 330i
wtw Oxi 3310
WTW Oxi 3300i
wtw Oxi 3310 IDS
wtw Oxi 340i
wtw Oxi 315i
wtw Ox i340i
wtw Oxi 320
wtw Oxi 3205
wtw Oxi 3210
wtw Categories
Measuring Instruments
Accessories
Laboratory Equipment
Control Unit
Touch terminals
More wtw Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL