Sign In
Upload
Manuals
Brands
Danfoss Manuals
Water Filtration Systems
AHF 005
Danfoss AHF 005 Manuals
Manuals and User Guides for Danfoss AHF 005. We have
3
Danfoss AHF 005 manuals available for free PDF download: Design Manual, Operating Instructions Manual, Manual
Danfoss AHF 005 Design Manual (124 pages)
Advanced Harmonic Filter
Brand:
Danfoss
| Category:
Water Filtration Systems
| Size: 6.54 MB
Table of Contents
Table of Contents
3
1 Introduction
6
Purpose of the Design Guide
6
Document Version
6
Intended Use
6
Abbreviations, Symbols, and Conventions
6
Abbreviations
6
Conventions
7
Approvals and Certifications
7
CE Conformity and Labeling
7
CE Mark
7
Low Voltage Directive
7
EMC Directive
8
Machinery Directive
8
Erp Directive
8
UL Compliance
8
Safety
8
General Safety Principles
8
Qualified Personnel
8
2 Introduction to Harmonics and Mitigation
11
Harmonics and Mitigation
11
Linear Loads
11
Non-Linear Loads
11
The Effect of Harmonics in a Power Distribution System
13
Harmonic Mitigation Standards and Requirements
14
Application-Specific Requirements
14
Harmonic Mitigation Standards
14
Harmonic Mitigation
16
3 Basic Operating Principle of the AHF
17
Operating Principle
17
Power Factor
18
Capacitive Currents
19
Energy Efficiency
19
4 Requirements for Installation
20
Mechanical Mounting
20
Safety Requirements of Mechanical Installation
20
Mounting Requirements
22
Recommendations for Installation in Industrial Enclosures
22
Ventilation and Cooling Requirements
22
Requirements for IP20 and IP21/NEMA
23
Electrical Installation
25
Terminals - Short Overview
25
Terminals for Capacitor Disconnect
25
Wiring
27
Overtemperature Protection
27
Programming of Digital Inputs for Overtemperature Protection
27
5 Selection of Advanced Harmonic Filter
28
Selecting the Correct AHF
28
How to Calculate the Correct Filter Size
28
Calculation Example
28
Voltage Boost
28
Selection Tables
29
Capacitor Disconnect Contactors
35
Non-Danfoss Contactors
35
Accessories
36
IP21/NEMA 1 Upgrade Kit
36
IP21/NEMA 1 Upgrade Kit Without Built-In Capacitor Disconnect Circuitry
37
IP21/NEMA 1 Upgrade Kit with Built-In Capacitor Disconnect Circuitry
38
Backplate for IP20 and IP21
40
6 Programming
41
Parameter Descriptions
41
7 Specifications
51
General Specifications
51
Environmental Data
52
Power Loss and Acoustic Noise Level
53
Mechanical Dimensions
56
Terminal Specifications
62
IP20 Enclosures
67
IP21 Enclosures
83
Backplate Dimensions
91
Fuses
93
8 Spare Parts
95
Selection Tables
96
Capacitor Kits for Revisions 01 and
96
Capacitor Kits for Revision
99
Terminals
102
Fan and Fan Accessories for Revisions 01 and
105
Fan and Fan Accessories for Revision
108
Fuses and Fuse Accessories
116
9 Appendix
118
Energy Efficiency
118
Introduction to Energy Efficiency
118
IE and IES Classes
119
Power Loss Data and Efficiency Data
119
Losses and Efficiency of a Motor
120
Losses and Efficiency of a Power Drive System
120
Losses and Efficiency of a Power Drive System with Installed Filter
120
Calculation Example
121
Index
122
Advertisement
Danfoss AHF 005 Operating Instructions Manual (30 pages)
Brand:
Danfoss
| Category:
Water Filtration Systems
| Size: 0.69 MB
Table of Contents
Table of Contents
1
1 Safety
3
Warnings
3
Symbols Used in this Manual
3
Operator's Safety
3
Avoid Filter Module Damage
3
2 Description
5
Ordering Numbers, 380 - 415 V, 50 Hz
6
Ordering Numbers, 380 - 415 V, 60 Hz
7
Ordering Numbers, 440 - 480 V, 60 Hz
8
Ordering Numbers, 500 - 525 V, 50 Hz
9
Ordering Numbers, 690 V, 50 Hz
10
Calculation of the Exact Filter Size Needed
10
3 Specifications
11
General Technical Data
11
Environmental Data
11
Dimensions/Weight
12
Dimension Diagrams
14
4 Installation
19
Mechanical Installation
19
Ventilation
19
Power Wiring
20
Capacitor Disconnect
20
Fuses
21
Over Temperature Contactor
23
Power Wiring Size
23
Operation on Different Mains Type
24
Typical Installation in a Panel or Other Enclosures
24
5 Commissioning
27
6 Appendix: Safety and Application Notes
29
General
29
Application as Directed
29
Transport, Storage
29
Installation
29
Danfoss AHF 005 Manual (22 pages)
Harmonic Filter
Brand:
Danfoss
| Category:
Water Filtration Systems
| Size: 0.58 MB
Table of Contents
Table of Contents
1
Safety
2
Warnings
2
Symbols Used in this Manual
2
Operator's Safety
2
Avoid Filter Module Damage
2
DC-Link Resonance
2
Description
3
Ordering Numbers, 380 - 415 V, 50 Hz
4
Ordering Numbers, 440 - 480 V, 60 Hz
5
Ordering Numbers, 500 V, 50 Hz
5
Calculation of the Exact Filter Size Needed
6
Specifications
7
General Technical Data
7
Environmental Data
8
Dimensions/Weight
9
Dimension Diagrams
11
Installation
14
Mechanical Installation
14
Ventilation
14
Power Wiring
15
Overtemperature Contactor
16
Power Wiring Size
17
Operation on Different Line Type
17
Typical Installation in a Panel or Other Enclosures
19
Commissioning
20
Appendix: Safety and Application Notes for
21
General
21
Application as Directed
21
Transport, Storage
21
Installation
21
Electrical Installation
21
Operation
22
Maintenance and Service
22
Advertisement
Advertisement
Related Products
Danfoss VLT AHF 005
Danfoss VLT AHF 010
Danfoss AHF 010
Danfoss VLT AAF00x
Danfoss APP 1.0
Danfoss APP 11
Danfoss AVT/VGUF
Danfoss AME 438 SU
Danfoss AVP PN25 25
Danfoss Akva Lux II
Danfoss Categories
Controller
DC Drives
Thermostat
Control Unit
Air Compressor
More Danfoss Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL