3.

Care, cleaning and maintenance

3.
Care, cleaning and maintenance
Cladding:
Clean the boiler cladding with a moist cloth as needed. In the event of heavy soiling, use soapy water or diluted suds
(do not use strong cleaners or sharp cleaning instruments).
Coasting surfaces:
Every millimetre of soot on the coasting surfaces means about 5 % more fuel consumption. A clean boiler saves
fuel and protects the environment.
Save fuel – always clean the boiler in good time!
Information!
The specified cleaning intervals are for guidance only! The cleaning intervals vary depending on
the quality of the fuel, the nature of operation and the different operating phases (e.g. a lot of par-
tial load, the blower spending a lot of time stationary during operations).

3.1 During each fill:

3.1.1 Lever for cleaning heating surfaces

– Press lever for cleaning heating surfaces 5–10 times – Fig. 58.
Fig. 58 Hebel-Heizflächenreinigung 5–10 x betätigen
3.1.2 Ignition openings on lighting door
Check ignition openings on lighting door and vertical grate, clear if necessary – Fig. 59.
Fig. 59 Checking ignition openings
1 Only for LogWIN with automatic ignition (accessory).
1
and vertical grate
Ignition opening on lighting door
Ignition opening on vertical grate
25