2.
Operation
2.8.4 Replenishing fuel – continuing heating operation
Attention!
Open the filling door carefully (due to the risk of deflagration).
1.) Press the lever for cleaning heating surfaces around 5–10 times for each fill
2.) Open the filling door as far as the stop against the catch, wait at least 15 seconds to allow low temperature
carburisation gases to be sucked away. Lift the hook catch, open the filling door all the way.
3.) Embers check:
we recommend only replenishing fuel once the wood has already burnt down.
– if there are still sufficient embers left, spread them evenly throughout the filling chamber and replenish
the fuel as required.
– if there are no embers or only a few, the system will need heating up again – see section 2.8.1.
4.) Close filling door and cladding door.

2.9 End of burning

At the end of combustion, the blower continues running until the combustion chamber has cooled down, in or-
der to make best use of the remaining embers depending on the burnout mode selected. Then it switches off
(Standby operating phase).