7.2 SERVICE MODE - SETUP TAB - CONTINUED
CHAPTER 7: SERVICE MODE
1) Enter into Service Mode (ENTER, 3, 0, 0, 1, ENTER).
2) Check if the Machine Type is set for R3xe.
3) As long as the Machine Type is correct, the console
should automatically be set for EP604 and the platform should
automatically be set for RB91.
4) Input the serial number for the console first.
5) The serial number configuration is as follows, then press OK:
- V:YY:MM;nnnnn
- V is the version. This will be a letter between B-Z (if the
console is version A, just leave this blank).
- Y is the year (e.g. 10, 11, 12).
- MM is the month (e.g. 08, 09, 10).
- nnnnn is the actual serial number.
Repeat this procedure to enter the platform serial number.
6) The example shows the console automatically set for EP604, a
version of A, a year of 2011, a month of 02 (February), and a serial
number of 00030.
The example shows the platform automatically set for RB91, a
version of A, a year of 2010, a month of 12 (December), and a
serial number of 00700.