Sanyo VCC-9000EBCP/EBSP Instruction Manual page 5

Table of Contents

Advertisement

PART NAMES • SETTINGS • SETUP1
Settings
1
SW2
2
SW1
1
Protocol and communication speed settings
ON
1
2
3
Protocol
Protocol setting
This sets the communication protocol to use for the
camera.
The default setting is the "SANYO" protocol (all OFF).
List of Protocol Settings
Protocol
1
SANYO
PELCO_D
ON
Communication speed setting
The default setting is "19200".
Communication
speed (bps)
2400
4800
9600
19200
SW2
4
5
6
7
8
Communication speed
SW2 number
2
3
4
5
SW2 number
7
8
OFF
OFF
ON
OFF
OFF
ON
ON
ON
VCC-9000EBCP/EBSP, VCC-9100EBCP/EBSP
2
Address settings
The default setting is "000" (all OFF).
Refer to "LIST OF ADDRESS SETTINGS (SW1)" for
address settings. (See p42)
3
Termination setting (JP3)
The termination connection setting must be made if this
camera is connected to a network system and it is in the
termination connection position.
The default setting is OFF (pins 2–3), so pull out the circuit
board and set JP3 to ON (short pins 1–2), then return the
6
circuit board to its original position.
If the camera is connected to a network system and it is
not in the termination connection position, the setting does
not need to be changed.
Pin positions
1–2
2–3
4
Communication setting (JP4)
The camera can be set for either RS-485 or coaxial
(default setting) communication.
The factory default setting is for coaxial communication
(pins 1–2), so that if you would like to use RS-485 control,
pull out the circuit board, change the setting to RS-485
(pins 2–3) and then reinsert the circuit board.
Pin positions
1–2
2–3
- 4 -
3
4
JP3
JP4
1 2 3 1 2 3
JP3
JP4
4
3
Communication
Termination
setting pins
setting pins
SW1
ON
1
2
3
4
5
6
7
8
Termination settings
ON
OFF
Connection method
setting
Coaxial (COAX)
RS485
English

Advertisement

Table of Contents
loading

Table of Contents