Dynamics Button; Gas Test Button; Wire Inch Button; Channel - Kemppi KempArc Pulse 350 Operating Manual

Table of Contents

Advertisement

5.2

dynAmICs Button

2.
Short press: Dynamics setting if welding process is mig/Synergic mig. Forming pulse setting if
welding process is Wiseroot/Wisethin.
5.3

gAs tEst Button

3.
gas test function.
pressing the button will show the gas test time. gas test time can be adjusted by using the
pulse encoder.
gas test will proceed after time adjustment is complete (short delay).
gas test can be stopped by pressing any button.
gas test
the gas test button opens the gas valve without activating the wire feed or power source. By
default, gas flows for 20 seconds. the gas flow time remaining is shown on the display.
the right-hand knob allows you to set the default gas flow time, between 10 and 60 seconds,
and store the new default value in the machine's memory. to stop the gas test, press the eSC
button.
5.4

wIrE InCh Button

4.
Wire Feeder will start immediately when the button is pressed.
the default wire inch speed is 1.0m/min.
Wire inch speed can be adjusted (+/-) using the pulse encoder.
When the button is released the Wire Feeder will stop. if the button is pressed again, the wire
feeder starts again and slopes to selected wire feed speed (if higher speed is adjusted).
5.5

ChAnnEl -

5.
memory channel down selection.
panel jumps directly to the previous memory channel that can be found from memory.
5.6
ChAnnEl +
6.
Short press: memory channel up selection.
panel jumps directly to next memory channel that can be found from memory.
at startup the machine uses the default memory channel selected by the robot.