Kemppi KempArc Pulse 350 Operating Manual page 15

Table of Contents

Advertisement

douBlE pulsE mIg
WFSpeed
0.7 – 25 m/min
WFS-Max
WFS-Min
FineTuning
FineTuningMax
0 – 9
FineTuningMin
-9 – 0
Dynamics
-9 – 9
Pulse Current
-10% – 15%
DPulseAmp
0.1 – 3.0 m/min
DPulseFreq
0.4 – 8.0 Hz
wIsEroot / wIsEthIn
)
WFSpeed
0.7 – 14 m/min
WFS-Max
WFS-Min
BaseCurrent
BaseCurrentMax
0 – 50 %
BaseCurrentMin
-50 – 0 %
FormingPulse
FormingPulseMax
0 – 50 %
FormingPulseMin
-50 – 0 %
StartTime
-9 – 9
StartVoltage
0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
Set the limit for maximum WFSpeed
Set the limit for minimum WFSpeed
Factory setting is 0
Adjusts the base current of the curve in certain limits.
( = curve point)
In other words, it adjusts the length of the arc in certain
limits.
0.5 steps
Set the limit for maximum arc length
0.5 steps
Set the limit for minimum arc length
Factory setting is 0
Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
Factory Setting
Reduces the pulse current of the curve at the maximum
is 0%
10% and raises it at the maximum 15%
Factory setting is
Adjusts the amplitude of the WFSpeed in 0.1 m/min
CURVE
steps. Value comes from Welding Curve.
Factory setting is
Adjusts the frequency of the double pulse in 0.1 Hz
CURVE
steps. Value comes from Welding Curve.
0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
Set the limit for maximum WFSpeed
Set the limit for minimum WFSpeed
Adjusts the base current of the curve in certain limits. In
other words, it adjusts the "length of the arc" in certain
limits.
1% steps
Set the limit for maximum "arc length"
1% steps
Set the limit for minimum "arc length"
Adjusts the forming pulse current of the curve in certain
limits. In other words, it controls arc pressure.
1% steps
Set the limit for maximum forming pulse current
1% steps
Set the limit for minimum forming pulse current
Factory setting is
Set how long arc behaves like normal synergic MIG/
CURVE
MAG prosess after the arc start. It gives heat for the arc
start.
Set the arc voltage which is used during StartTime.
In other words, it adjusts the length of the arc during
StartTime.
EN
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kemparc 450Kemparc dt 400

Table of Contents