Kemppi KempArc Pulse 350 Operating Manual page 17

Table of Contents

Advertisement

systEm ConFIg mEnu
Water Cooling
Water Cooler control:
OFF / AUTO / ON.
Cable Length
Cable length: 10m -
100m, 5m steps.
FineCalib
Fine Tuning
Calibration Point:
0V/100A –
100V/100A,
1V steps.
System Clock
Device
System Device information:
DevSW: Unit Software Version.
Information
SysSW: System Software Version (Base software version).
BootSW: Boot Software Version.
SW Item: Software Item Number (IFS number).
Serial: Device Serial number.
Prog: Programmer name
Date: Programming date.
Restore Settings
User 1 (one of ten users) Channel:
Selected user can restore to his backup memory channels one by one.
Other users' memory channels remain untouched.
Setup settings remain untouched.
User 1 (one of ten users) All Channels:
Selected user can restore all of his backup memory channels (0-9) at one time.
Other users' memory channels remain untouched.
Setup settings remain untouched.
Restore To Factory:
All channels (of all users) are removed.
All users' backup channels are removed.
All setup settings are set to defaults.
Licence Code
Entering Licence Code numbers:
Up/Down arrows are used to select the code number position.
Pulse encoder is used to select the code number (0-255) to be entered.
Soft Key Button on the right is used to activate the license number (after all numbers have been
entered). In case the code was wrong the earlier view will be displayed.
WeldData Delay
Adjustment Range:
1s – 60s
1s steps.
Display Delay
Adjustment Range:
1 – 20
1 steps.
Pre Gas Time
Pre Gas Time setting:
0.0s – 9.9s – CURVE,
0.1s steps.
Post Gas Time
Post Gas Time setting:
0.0s – 9.9s - CURVE
0.1s steps.
(in main menu 4/7)
Factory setting: AUTO
Factory Setting: 10m.
Factory Setting: 10V/100A.
System Clock Settings.
Factory Setting: 20s.
Factory Setting: 10.
Factory Settings: CURVE.
Factory Settings: CURVE.
OFF: Water Cooler always OFF.
AUTO: Water Cooler automatic control
ON. Water Cooler starts when welding
starts and is turned off after a delay when
welding stops.
ON: Water Cooler is always ON.
Welding cable loop length setting for
optimising arc control.
Compensation for varying cable resistance.
Defines how long the Weld Data is
displayed after Welding Ends.
Weld Data display is also turned off when
pulse encoder is turned or any button is
pressed.
Defines how long time the information is
displayed (like: "Setting Saved" text). This is
not always the exact time.
CURVE: Pre Gas time is read from the
Welding Curve.
0.0 - 9.9s: User Pre Gas time setting.
CURVE: Pre Gas time is read from the
Welding Curve.
0.0 - 9.9s: User Post Gas time setting.