15
. IGNITION SYSTEM
CDI UNIT INSPECTION
Remove the front cover screws.
Disconnect the CDI coupler and remove the
CDI unit.
Measure the resistance between the
terminals using the electric tester.
.
*
• Due to the semiconductor in circuit, it is
necessary to use a specified tester for
accurate testing. Use of an improper
tester in an improper range may give
false readings.
• Use a Sanwa Electric Tester or Kowa
Electric Tester.
• In this table, "Needle swings then
returns" indicates that there is a charging
current applied to a condenser. The
needle will then remain at "∞" unless the
condenser is discharged.
Probe⊕
B/L
B/Y
(-)Prob
e
∞
B/L
B/Y
8-10M
L/Y
8-10M 0.6-1K
↑
↓
V/B
250-
V/R
8-11M
400K
G
8-10M 1-3K 0.6-1K
Unit: Ω
L/Y
V/B
V/R
G
∞
∞
∞
∞
250-
∞
0.6-1K
1-3K
400K
250-
∞
0.6-1K
400K
↓
↓
↓
250-
250-
∞
400K
400K
250-
∞
400K
CDI Unit
V/R
V/B
G
L/Y
PEOPLE S 4T
B/L
B/Y
15-4