Intermec CK30 User Manual page 122

Hide thumbs Also See for CK30:
Table of Contents

Advertisement

Chapter 5 — Running Diagnostics
The Main Bat field displays the voltage of the AB1G battery.
The following table shows how to interpret the voltage levels.
Main
Battery Status
High
High
Medium
Low
Critically low
The Main Batt Flag field displays the battery status, which is
linked to the battery icon described on page 8. You can continue
using the battery until the CK30 indicates that the battery is
low: the battery light turns on and the low battery icon (
appears on the taskbar.
The Supercap field displays the voltage of the backup battery.
The main battery continually charges the backup battery unless
the main battery is critically low or removed.
Backup
Battery
Status
High
High
Low
Low
There are some usage patterns that can cause the backup battery
to become depleted. For example, if you remove the main
battery every night to charge it outside the CK30, the backup
battery will be low in the morning. This usage pattern does not
harm the backup battery.
When the backup battery is low, the Backup Battery Very Low
dialog box appears on your CK30 screen.
108
Main Battery Voltage
8500 mV
> 8000 mV
7600 to 7999 mV
7200 to 7599 mV
< 7199 mV
Backup Battery
Voltage
Condition
> 2400 mV
Fully charged
> 2200 mV
OK to swap the main battery
> 1750 mV
OK to swap the main battery if
you first suspend the CK30
< 1750 mV
Do not swap the main battery
because the CK30 might cold
boot
CK30 Handheld Computer User's Manual
Percentage
of Battery
100%
> 75%
50% to 75%
25% to 50%
< 25%
)