The switch performs a self-diagnostic test upon power on, and takes
about 20 seconds to complete.
5.
Make sure the Power LED on the front panel lights green.
6.
Attach the data cables and observe normal operation as indicated by
the port LEDs. Use only one Port 8, either Port 8 MDI or Port 8 MDI-X.

Rackmount Installation

Rackmount installation applies to the AT-FS708 only. You will need a Phillips
screwdriver for this installation.
Do not use power tools to perform this installation.
1.
If previously attached, remove the rubber feet and all cables and
power cord from the switch.
2.
Attach the rackmounting brackets to each side of the switch, using the
screws provided.
3.
Attach the power cord to the back of the switch.
4.
Position the switch in a standard 19-inch rack and secure the switch's
brackets to the rack using the 4 large screws provided.
5.
Plug the power cord into the power receptacle. Make sure the Power
LED on the front panel lights green.
6.
Attach the data cables and observe normal operation as indicated by
the port LEDs. Use only one Port 8, either Port 8 MDI or Port 8 MDI-X.
For typical configuraiton information, refer to "Configuration" on
page 10.
Auto-negotiation for transmission mode supports full-duplex only if
the connected device also negotiates for full-duplex transmission mode.
You are finished with rackmount installation.