  • Page 1: Ethernet Switch

    Layer 2 Fast Ethernet Switch AT-FS708POE Installation Guide 613-000267 Rev. D...
  • Page 2 Allied Telesis, Inc. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesis, Inc. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesis, Inc.
  • Page 3: Electrical Safety And Emissions Standards

    European Union Restriction of the Use of Certain Hazardous Substances (RoHS) in Electrical and Electronic Equipment This Allied Telesis RoHS-compliant product conforms to the European Union Restriction of the Use of Certain Hazardous Substances (RoHS) in Electrical and Electronic Equipment. Allied Telesis ensures RoHS conformance by requiring supplier Declarations of Conformity, monitoring incoming materials, and maintaining manufacturing process controls.
  • Page 4: Translated Safety Statements

    Translated Safety Statements Important: The indicates that a translation of the safety statement is available in a PDF document titled “Translated Safety Statements” posted on the Allied Telesis website at www.alliedtelesis.com and on the documentation CD shipped with this product.
  • Page 5: Table Of Contents

    Contents Preface ....................................11 Safety Symbols Used in this Document..........................12 Where to Find Web-based Guides ............................13 Contacting Allied Telesis ..............................14 Online Support ................................14 Email and Telephone Support ............................14 Returning Products................................14 For Sales or Corporate Information ..........................14 Warranty ..................................14 Chapter 1: Overview ................................15 Features ....................................16...
  • Page 6 Power Cord Specifications..............................50 Safety and Electromagnetic Emissions Certifications......................51 RJ-45 Twisted Pair Port Connectors and Pinouts ........................52...
  • Page 7 Figures Figure 1. AT-FS708POE Fast Ethernet Switch Front and Back Panels ................16 Figure 2. SFP Transceiver..............................18 Figure 3. Power Workgroup Topology ..........................26 Figure 4. PoE Network Topology............................27 Figure 5. Attaching the Rubber Feet ...........................35 Figure 6. Attaching Brackets for Wall Mounting........................36 Figure 7.
  • Page 8 Figures...
  • Page 9 Tables Table 1. Safety Symbols ..............................12 Table 2. System LED ................................19 Table 3. Twisted Pair Port LEDs ............................19 Table 4. SFP Port LED ...............................19 Table 5. IEEE 802.3af Class vs. Power Levels ........................22 Table 6. Twisted Pair Cabling and Distances ........................33 Table 7.
  • Page 10 Tables...
  • Page 11: Preface

    Preface This guide provides the hardware installation instructions for your AT-FS708POE Fast Ethernet switch. This preface contains the following sections: “Safety Symbols Used in this Document” on page 12 “Where to Find Web-based Guides” on page 13 “Contacting Allied Telesis” on page 14...
  • Page 12: Safety Symbols Used In This Document

    Preface Safety Symbols Used in this Document This document uses the safety symbols defined in Table 1. Table 1. Safety Symbols Symbol Meaning Description Caution Performing or omitting a specific action may result in equipment damage or loss of data. Warning Performing or omitting a specific action may result in electrical shock.
  • Page 13: Where To Find Web-Based Guides

    AT-FS708POE Fast Ethernet Switch Installation Guide Where to Find Web-based Guides The installation and user guides for all Allied Telesis products are available in portable document format (PDF) on our web site at www.alliedtelesis.com. You can view the documents online or download...
  • Page 14: Contacting Allied Telesis

    Email and For Technical Support via email or telephone, refer to the Allied Telesis web site: www.alliedtelesis.com. Select your country from the list Telephone displayed on the website. Then select the appropriate menu tab.
  • Page 15: Chapter 1: Overview

    Chapter 1 Overview This chapter contains the follows sections: “Features” on page 16 “Port Descriptions” on page 17 “LEDs” on page 19 “Power Supply” on page 20 “Power over Ethernet” on page 21 “Ethernet Switching Basics” on page 23 “Network Topologies” on page 26...
  • Page 16: Features

    8 port 10/100TX Unmanaged POE Switch w/1 SFP port PD ON PD ERR UPLINK PORT POWER CLASS 1 LASER PRODUCT 1000Base-X Power LED SFP Port (Uplink Port) 10/100Base-T Twisted Pair Ports Uplink Port LED AC Power Connector Figure 1. AT-FS708POE Fast Ethernet Switch Front and Back Panels...
  • Page 17: Port Descriptions

    AT-FS708/POE Fast Ethernet Switch Installation Guide Port Descriptions The following sections describe the types of ports on the AT-FS708/POE Fast Ethernet switch: “Twisted Pair Ports,” next “SFP Port” on page 18 Twisted Pair The AT-FS708/POE Fast Ethernet switch features eight 10/100Base-T twisted pair ports.
  • Page 18: Sfp Port

    Chapter 1: Overview ports. SFP Port The AT-FS708/POE switch has one SFP port that can accommodate an optional Small Form-factor Pluggable (SFP) transceiver. The SFP transceiver is a fast and easy way for you to add an 1000 Mbps fiber optic uplink port to your Fast Ethernet switch. You can use the SFP to extend the distance of your network, build a high-speed backbone network between switches, or connect additional end nodes to the network, such as high-speed servers.
  • Page 19: Leds

    AT-FS708/POE Fast Ethernet Switch Installation Guide LEDs The system and port LEDs on the front panel of the AT-FS708/POE Fast Ethernet switch switch display the switch and its port status information. Table 2 describes the system LED. Table 2. System LED State Description Green...
  • Page 20: Power Supply

    Chapter 1: Overview Power Supply The AT-FS708/POE Fast Ethernet switch has an internal power supply with a single AC power supply socket on the back panel which features autoswitch AC inputs. To power the switch on or off, connect or disconnect the power cord provided with the switch.
  • Page 21: Power Over Ethernet

    AT-FS708/POE Fast Ethernet Switch Installation Guide Power over Ethernet The twisted pair ports on the AT-FS708/POE Fast Ethernet switch feature Power over Ethernet (PoE). PoE is a mechanism for supplying power to network devices over the same twisted pair cables used to carry network traffic.
  • Page 22: Implementation

    Chapter 1: Overview Note Power is supplied to the powered devices in the order that the ports are connected or on a first-come-first-served basis until the 65 watt limit is reached. If the switch is power cycled after the PoE devices are connected to the switch ports, the power is supplied to ports 1 through 8 in that order.
  • Page 23: Ethernet Switching Basics

    AT-FS708/POE Fast Ethernet Switch Installation Guide Ethernet Switching Basics An Ethernet switch interconnects network devices, such as workstations, printers, routers, and other Ethernet switches, so that they can communicate with each other by sending and receiving Ethernet frames. MAC Address Every hardware device on your network has a unique MAC address.
  • Page 24: Store And Forward

    Chapter 1: Overview end node can receive or transmit data, but not both simultaneously, the end node is operating in what is referred to as half-duplex mode. If an end node can both receive and transmit data simultaneously, the end node is said to be operating in full-duplex mode.
  • Page 25 AT-FS708/POE Fast Ethernet Switch Installation Guide sending data. This can occur under several circumstances. For example, if two end nodes are operating at different speeds, the switch, while transferring data between the end nodes, might need to instruct the faster end node to stop transmitting data to allow the slower end node to catch up.
  • Page 26: Network Topologies

    Chapter 1: Overview Network Topologies This section illustrates two network topologies that you can create with the AT-FS708/POE Fast Ethernet switch: a power workgroup and collapsed backbone. Both types of topologies are described below. Power The topology shown in Figure 3 is commonly referred to as a power workgroup topology.
  • Page 27: Poe Network Topology

    AT-FS708/POE Fast Ethernet Switch Installation Guide PoE Network In the topology shown in Figure 4, an AT-FS708/POE Fast Ethernet switch is connected to an AT-9424T/SP Gigabit Ethernet Switch and a number of Topology power devices in different destinations. Using the AT-FS708/POE Fast Ethernet switch, you can generate a complete POE Security network at a fraction of the cost.
  • Page 28 Chapter 1: Overview...
  • Page 29: Chapter 2: Installation

    Chapter 2 Installation This chapter contains the following sections: “Reviewing Safety Precautions” on page 30 “Selecting a Site for the Switch” on page 32 “Planning the Installation” on page 33 “Unpacking the Switch” on page 34 “Installing the Switch on a Table or Desktop” on page 35 “Mounting the Switch on a Wall”...
  • Page 30: Reviewing Safety Precautions

    Note indicates that a translation of the safety statement is available in a PDF document titled “Translated Safety Statements” on the Allied Telesis website at www.alliedtelesis.com and on the documentation CD shipped with this product. Warning: Class 1 Laser product.
  • Page 31 AT-FS708/POE Fast Ethernet Switch Installation Guide Warning: Operating Temperature. This product is designed for a maximum ambient temperature of 40° degrees C. All Countries: Install product in accordance with local and National Electrical Codes. Caution: The attached mounting brackets must be used to securely mount the device on the wall.
  • Page 32: Selecting A Site For The Switch

    Chapter 2: Installation Selecting a Site for the Switch Observe the following requirements when choosing a site for the AT-FS708/POE Fast Ethernet switch: If you plan to install the switch in an equipment rack, be sure that the rack is safely secured and that it will not tip over. Devices in a rack should be installed starting at the bottom, with the heavier devices near the bottom of the rack.
  • Page 33: Planning The Installation

    AT-FS708/POE Fast Ethernet Switch Installation Guide Planning the Installation Table 6 contains the cabling specifications for the twisted pair ports. Table 6. Twisted Pair Cabling and Distances Maximum Speed Type of Cable Operating Distance 10 Mbps Category 3 or better 100-ohm shielded 100 m (328 ft) or unshielded twisted pair cable 100 Mbps...
  • Page 34: Unpacking The Switch

    Chapter 2: Installation Unpacking the Switch To unpack an AT-FS708/POE Fast Ethernet switch, perform the following procedure: 1. Remove all components from the shipping package. Note Store the packaging material in a safe location. You must use the original shipping material if you need to return the unit to Allied Telesis.
  • Page 35: Installing The Switch On A Table Or Desktop

    AT-FS708/POE Fast Ethernet Switch Installation Guide Installing the Switch on a Table or Desktop To install the switch on a table or desktop, perform the following procedure: 1. Remove all the items from the packaging and store the packaging material in a safe place. In the event a problem occurs and you need to return the unit, please use as much of the original shipping material as possible.
  • Page 36: Mounting The Switch On A Wall

    Chapter 2: Installation Mounting the Switch on a Wall You can mount the AT-FS708/POE Fast Ethernet switch on the wall in a vertical position using the mounting brackets that are shipped with the switch. The wall-mounting screws, plastic anchors, and other materials necessary to mount the switch on a wall are not provided.
  • Page 37: Figure 7. Mounting The Switch On The Wall

    AT-FS708/POE Fast Ethernet Switch Installation Guide 5. Mount the switch on the wall using the wall mounting screws (not provided), as shown in Figure 7. Figure 7. Mounting The Switch on the Wall 6. Refer to “Cabling and Powering on the Switch” on page 43 to attach ethernet cables and power cable.
  • Page 38: Installing The Switch In A Rack

    Chapter 2: Installation Installing the Switch in a Rack To install the switch in a rack, perform the following procedure: 1. If attached, remove the rubber feet using a flat-head screwdriver. 2. Attach a mounting bracket (provided) to each side of the switch using the bracket mounting screws (provided), as shown Figure 8.
  • Page 39: Figure 9. Mounting The Switch On The Rack

    AT-FS708/POE Fast Ethernet Switch Installation Guide Figure 9. Mounting the Switch on the Rack Warning: To prevent electric shock, do not remove the cover. No user-serviceable parts inside. This unit contains hazardous voltages and should only be opened by a trained and qualified technician.
  • Page 40 Chapter 2: Installation If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than the room ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
  • Page 41: Installing An Optional Sfp Transceiver

    Note You must use the original shipping material if you need to return the module to Allied Telesis. Warning: An SFP transceiver can be damaged by static electricity. Be sure to observe all standard electrostatic discharge (ESD) precautions, such as wearing an antistatic wrist strap, to avoid damaging the transceiver.
  • Page 42: Figure 10. Inserting The Sfp

    Chapter 2: Installation 4. Slide the SFP transceiver into the SFP slot on the switch, as shown in Figure 10. L IN K A C T P D O P D E U P L IN K P O R S F P 1 0 0 0 B a s e...
  • Page 43: Cabling And Powering On The Switch

    AT-FS708/POE Fast Ethernet Switch Installation Guide Cabling and Powering on the Switch This section contains the following procedures: “Cabling the Twisted Pair Ports,” next “Cabling an SFP Transceiver” on page 43 “Powering on the Switch” on page 45 Cabling the To connect to the 10/100Base-T twisted pair ports on the AT-FS708/POE switch, perform the following procedure: Twisted Pair...
  • Page 44: Figure 12. Removing The Dust Cover From The Sfp Transceiver

    Chapter 2: Installation Warning Class 1 laser product. Warning Do not stare into the laser beam. Note For information about the proper cable type, refer to the documentation that accompanied the SFP transceiver. Note Before you install the cable in the SFP transceiver, verify that the optical power input to the transceiver is within its dynamic range.
  • Page 45: Powering On The Switch

    AT-FS708/POE Fast Ethernet Switch Installation Guide 3. Power on the end nodes. Powering on the To power on the AT-FS708/POE Fast Ethernet switch, perform the following procedure: Switch 1. Plug the power cord into the AC power connector on the back panel of the switch, as shown in Figure 14.
  • Page 46 Chapter 2: Installation...
  • Page 47: Chapter 3: Troubleshooting

    Note If after following the instructions in this chapter you are unable to resolve the problem, contact Allied Telesis Technical Support for assistance. Refer to “Contacting Allied Telesis” on page 14 for contact information. PWR LED is Off If the LED is OFF, indicating that the unit is not receiving power, do the...
  • Page 48 Chapter 3: Troubleshooting Verify that you are using the appropriate category of twisted pair cable: Category 3 or better for 10 Mbps operation and Category 5 and Category 5E for 100 Mbps operation.
  • Page 49: Appendix A: Technical Specifications

    Appendix A Technical Specifications Physical Specifications Dimensions: (W x D x H) 330.2 mm x 220.8 mm x 43.5 mm (13.0 in x 8.7 in x 1.7 in) Weight: 1.81 kg (4.0 lbs) Environmental Specifications Operating Temperature: 0° C to 40° C (32° F to 104° F) Storage Temperature: -25°...
  • Page 50: Power Cord Specifications

    Appendix A: Technical Specifications Power Cord Specifications Cable Type: H05VV-F, 3G, 0.75mm Maximum Current: 6 Amps Voltage Rating: AC 250 VAC minimum...
  • Page 51: Safety And Electromagnetic Emissions Certifications

    AT-FS708/POE Fast Ethernet Switch Installation Guide Safety and Electromagnetic Emissions Certifications FCC Class A, CISPR 22 Class A, EN55022 Class A, C-TICK, CE Immunity EN55024 Electrical Safety UL 60950 ( ), EN60950 (TUV) or VDE Laser IEC/EN 60825-1, IEC/EN 60825-2...
  • Page 52: Figure 15. Rj-45 Connector And Port Pin Layout

    Appendix A: Technical Specifications RJ-45 Twisted Pair Port Connectors and Pinouts This section lists the connectors and connector pinouts for the AT-FS708/POE Fast Ethernet switch and its components. Figure 15 illustrates the pin layout to an RJ-45 connector and port. Figure 15.