Cabling Specifications; Electrical Specifications; Utp (Rj45) Connector; Low Last Bit-To-First Delay - Allied Telesis AT-FS708 Installation Manual

Hide thumbs Also See for AT-FS708:
Table of Contents

Advertisement

Switch Specifications

Cabling Specifications

10Base-T:
100Base-TX:
100 m (328 ft) between switch and network node.

Electrical Specifications

AT-FS708 Internal Power:
AT-FS708E External Power:

UTP (RJ45) Connector

Figure 7 shows an RJ45 connector. For a 100Base-TX link between switches,
—any two Medium Attachment Units (MAUs)—you need a crossover cable. For
a connection to a Network Interface Controller (NIC), the cable is wired
straight-through.

Low Last Bit-to-First Delay

For long packets:
For short packets:
18
STP/UTP Category 3,4,5 100 ohm impedance
STP/UTP Category 5 wiring, 100 ohm
impedance
Internal universal power supply with
100 to 240 VAC, 50/60 Hz, 0.3 A input.
External power adaper provides 13-19
UDC, 800 mA maximum.
Pin 1
Figure 7 RJ45 Connector
<30 µs
<18 µs
Pin 8

Hide quick links: