Allied Telesis AT-FS708/POE Installation Manual

Fast ethernet poe switch

Advertisement

Installation
Guide
PN 613-000267 Rev B

Fast Ethernet

POE Switch
AT-FS708/POE
®

Advertisement

Table of Contents
loading

Summary of Contents for Allied Telesis AT-FS708/POE

  • Page 1: Fast Ethernet

    Fast Ethernet POE Switch ® AT-FS708/POE Installation Guide PN 613-000267 Rev B...
  • Page 2 Allied Telesyn, Inc. has been advised of, known, or...
  • Page 3: Electrical Safety And Emissions Standards

    Electrical Safety and Emissions Standards This product meets the following standards. U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules.
  • Page 4 Electrical Safety and Emissions Standards Translated Safety Statements Important: Appendix B contains translated safety statements for installing this equipment. When you see the , go to Appendix B for the translated safety statement in your language. Wichtig: Anhang B enthält übersetzte Sicherheitshinweise für die Installation dieses Geräts. Wenn sehen, schlagen Sie in Anhang B den übersetzten Sicherheitshinweis in Ihrer Sprache nach.
  • Page 5: Table Of Contents

    Electrical Safety and Emissions Standards ........................3 Preface ....................................7 How This Guide is Organized .............................. 7 Document Conventions ............................... 8 Contacting Allied Telesyn ..............................9 Online Support ................................9 Email and Telephone Support ............................9 Returning Products...............................9 For Sales or Corporate Information ..........................9 Chapter 1 Product Description ...............................
  • Page 6 Contents Appendix A Technical Specifications ..............................42 Physical Specifications ..............................42 Environmental Specifications............................. 42 Power Specifications................................42 Power Cord Specifications..............................42 Safety and Electromagnetic Emissions Certifications......................43 Compliance Standards............................... 43 RJ-45 Twisted Pair Port Connectors..........................44 Appendix B Translated Safety Statements ............................45...
  • Page 7: Preface

    Preface This guide contains the hardware installation instructions for the AT-FS708/POE Fast Ethernet Switch. How This Guide is Organized This manual contains the following chapters and appendices: Chapter 1, ”Product Description”, describes the features and components of the switch. Chapter 2, ”Installation”, contains the installation instructions for the switch.
  • Page 8: Document Conventions

    Preface Document Conventions This document uses the following conventions to highlight important information: Note Notes provide additional information. Warning Warnings inform you that performing or omitting a specific action may result in bodily injury. Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data.
  • Page 9: Contacting Allied Telesyn

    To obtain a RMA number, contact Allied Telesyn’s Technical Support at our web site: http://www.alliedtelesyn.com. For Sales or You can contact Allied Telesyn for sales or corporate information at our web site: http://www.alliedtelesyn.com. To find the contact information Corporate for your country, select “Contact Us”, then “Worldwide Contacts”.
  • Page 10: Product Description

    Chapter 1 Product Description This chapter contains the follows sections: “Overview” on page 11 “Power-over-Ethernet (PoE)” on page 13 “Key Features” on page 15 “Standards” on page 15 “Hardware Feature Description” on page 16 “A Few Ethernet Switching Basics” on page 20 “Network Topologies”...
  • Page 11: Overview

    The PoE ports allow data and power be transmitted over the same single twisted pair cable without power sourcing consideration or electric rewires. The AT-FS708/POE switch features eight 10/100 Mbps PoE ports and one SFP expansion slot. Four out of the eight PoE ports can be fully powered...
  • Page 12 10 Mbps or 100 Mbps and in half- or full-duplex mode. The AT-FS708/POE switch can be used on a desktop, mounted to a wall or in rack. The switch is easy to install and does not require software...
  • Page 13: Power-Over-Ethernet (Poe)

    PoE Features The twisted pair ports on the AT-FS708/POE switch offer the same features and functionality as the twisted pair ports on the other switches in the series. As such, they can operate at 10 or 100 Mbps, feature Auto- Negotiation and Auto-MDI/MDI-X, and so forth.
  • Page 14: At-Fs708/Poe's Implementation Of Poe

    The PoE implementation on the AT-FS708/POE switch transmits power over the same strands that carry the network traffic. The power transfer does not interfere with the network traffic. The power and the network traffic can coexist on the same strands simultaneously.
  • Page 15: Key Features

    AT-FS708/POE Fast Ethernet Switch Installation Guide Key Features The AT-FS708/POE switch has the following key features: Eight RJ-45 10/100Base-TX PoE twisted pair ports One SFP expansion slot Power-over-Ethernet Powered Device (PD) Support System and port LEDs Auto MDI/MDI-X on all ports Auto-Negotiation (IEEE 802.3u-compliant)
  • Page 16: Hardware Feature Description

    Chapter 1: Product Description Hardware Feature Description The following sections describe hardware features of the AT-FS708/POE Fast Ethernet switch: Eight PoE twisted pair ports One SFP expansion slot System and Port LEDs AC power connector Twisted Pair The AT-FS708/POE Gigabit Ethernet switch features eight twisted pair ports.
  • Page 17: Sfp Expansion Slot

    SFP Expansion The AT-FS708/POE switch has one SFP expansion slot that can accommodate one optional Small Form-factor Pluggable (SFP) Slot transceiver module, also referred to as a mini-GBIC.
  • Page 18: Leds

    Chapter 1: Product Description LEDs The system and port LEDs on the front panel of the AT-FS708/POE switch display the switch and its port status information. Each port has two LEDs. Table 1 describes the system and twisted pair port LEDs on the AT-FS708/POE Fast Ethernet switch.
  • Page 19: Ac Power Connector

    AT-FS708/POE Fast Ethernet Switch Installation Guide AC Power The AT-FS708/POE Fast Ethernet switch has a single AC power supply socket on the back panel, which has an auto-switch AC inputs. Refer to Connector Appendix A, “Technical Specifications” on page 42, for the input voltage range.
  • Page 20: A Few Ethernet Switching Basics

    NIC already has a MAC address assigned to it by its manufacturer. The AT-FS708/POE Fast Ethernet switch can contain up to 8,000 entries on its MAC address table. The switch uses the table to store the MAC addresses of the network end-nodes connected to the ports, along with the port number on which each address was learned.
  • Page 21: Duplex Mode

    The twisted pair ports on the AT-FS708/POE switch can operate in half- or full-duplex mode for 10/100 Mbps. They are IEEE 802.3u-compliant and use Auto-Negotiation to set the duplex mode setting for you automatically.
  • Page 22: Network Topologies

    Chapter 1: Product Description Network Topologies This section illustrates two network topologies that you can create with the AT-FS708/POE Fast Ethernet switch: a power workgroup and collapsed backbone. Both types of topologies are described below. Power The topology shown in Figure 4 is commonly referred to as a power workgroup topology.
  • Page 23: Poe Network Topology

    AT-FS708/POE Fast Ethernet Switch Installation Guide PoE Network In the topology shown in Figure 5, an AT-FS708/POE switch is connected to an AT-9424T/SP and a number of AT-FS705PD powered devices in Topology different destinations. Using the AT-FS708/POE switch in combination with the AT-FS705PD powered devices, you can generate a complete POE Security network at a fraction of the cost.
  • Page 24: Chapter 2 Installation

    Chapter 2 Installation This chapter contains the following sections: “Reviewing Safety Precautions” on page 25 “Selecting a Site for the Switch” on page 26 “Planning the Installation” on page 27 “Unpacking the Switch” on page 28 “Installing the Switch on a Table or Desktop” on page 29 “Installing the Switch in a Rack”...
  • Page 25: Reviewing Safety Precautions

    AT-FS708/POE Fast Ethernet Switch Installation Guide Reviewing Safety Precautions Please review the following safety precautions before you begin to install the switch or any of its components. Refer to “Translated Safety Statements” on page 45 for translated safety statements in your language.
  • Page 26: Selecting A Site For The Switch

    Selecting a Site for the Switch Observe the following requirements when choosing a site for the AT-FS708/POE Fast Ethernet Switch: If you plan to install the switch in an equipment rack, be sure that the rack is safely secured and that it will not tip over. Devices in a rack should be installed starting at the bottom, with the heavier devices near the bottom of the rack.
  • Page 27: Planning The Installation

    AT-FS708/POE Fast Ethernet Switch Installation Guide Planning the Installation Table 3 contains the cabling specifications for the twisted pair ports. Table 3. Twisted Pair Cabling and Distances Maximum Speed Type of Cable Operating Distance 10 Mbps Category 3 or better 100-ohm...
  • Page 28: Unpacking The Switch

    Chapter 2: Installation Unpacking the Switch To unpack an AT-FS708/POE switch, perform the following procedure: 1. Remove all components from the shipping package. Note Store the packaging material in a safe location. You must use the original shipping material if you need to return the unit to Allied Telesyn.
  • Page 29: Installing The Switch On A Table Or Desktop

    AT-FS708/POE Fast Ethernet Switch Installation Guide Installing the Switch on a Table or Desktop To install the switch on a table or desktop, perform the following procedure: 1. Remove all the items from the packaging and store the packaging material in a safe place. In the event a problem occurs and you need to return the unit, please use as much of the original shipping material as possible.
  • Page 30 Chapter 2: Installation Warning The power cord is used as a disconnection device. To de-energize equipment, disconnect the power cord. 6. Verify that either the POWER LED is green. If the LED is OFF, refer to “Troubleshooting” on page 41 for instructions. Note The switch perform a self-diagnostic test upon power up.
  • Page 31: Installing The Switch In A Rack

    UP LI PO RT SF P 10 00 Ba se Figure 7. Attaching Brackets for Rackmounting Warning The chassis may be heavy and awkward to lift. Allied Telesyn recommends that you get assistance when mounting the chassis in an equipment rack.
  • Page 32 Chapter 2: Installation 3. Mount the switch in the 19-inch rack using the rackmounting screws (not provided), as shown in Figure 8. A T -F S 7 0 8 po rt 10 8 /P O /1 00 TX Un m an ag ed PO E Sw itc...
  • Page 33: Wall-Mounting The Switch

    Figure 9. Figure 9. Attaching Brackets for Wall-mounting Warning The chassis may be heavy and awkward to lift. Allied Telesyn recommends that you get assistance when mounting the chassis onto a wall. 4. Position the switch onto the wall with the front of the switch is against...
  • Page 34 Chapter 2: Installation Caution Make sure that the AT-FS708/POE switch is always mounted onto the wall with the front panel facing downwards and the back panel facing upwards. 5. Mount the chassis onto the wall using the wallmounting screws (not provided), as shown in Figure 10.
  • Page 35: Installing An Optional Sfp Module

    AT-FS708/POE Fast Ethernet Switch Installation Guide Installing an Optional SFP Module To install an optional SFP module in an AT-FS708/POE switch, perform the following procedure: Caution The laser light used by the SFP module is invisible. Standard safety precautions (e.g. avoid looking directly into a fiber optic port) should always be observed when installing or maintaining this product.
  • Page 36 Chapter 2: Installation SFP modules are dust sensitive. Do not remove the dust cover from the port until you are ready to attach the fiber optic cable. The most common source of contaminants in the optical bore is debris picked up on the ferrules of the optical connectors. Use an alcohol swab or wipe to clean the ferrules of the optical connector.
  • Page 37: Cabling The Switch

    AT-FS708/POE Fast Ethernet Switch Installation Guide Cabling the Switch To connect to the ports on the AT-FS708/POE switch, perform the following procedure: 1. Connect the twisted pair data cables to the RJ-45 ports on the switch, as shown in Figure 12.
  • Page 38: Connecting To A Sfp Transceiver Module

    Chapter 2: Installation Connecting to a To connect the fiber optic data cables to the SFP transceiver modules, perform the following procedure: SFP Transceiver Module Warning Class 1 laser product. Warning Do not stare into the laser beam. 1. Insert the SFP transceiver into the SFP expansion slot on the switch, as shown in Figure 11 on page 36.
  • Page 39 AT-FS708/POE Fast Ethernet Switch Installation Guide 3. Connect the fiber optic cable to the SFP transceiver, as shown in Figure 14. L IN K A C T P D O P D E U P L IN K P O R S F P Figure 14.
  • Page 40: Powering On The Switch

    Chapter 2: Installation Powering On the Switch To apply power to the AT-FS708/POE switch, perform the following procedure: 1. Apply AC power to the switch by plugging the power cord into the AC power connector on the back panel of the unit, as shown in Figure 15.
  • Page 41: Chapter 3 Troubleshooting

    If you are still unable to resolve the problem after following the instructions in this chapter, contact ATI Technical Support for assistance. Refer to “Contacting Allied Telesyn” on page 9. Check the POWER LED on the front of the switch. If the LED is OFF,...
  • Page 42: Technical Specifications

    Appendix A Technical Specifications Physical Specifications Dimensions: (W x D x H) 330.2 mm x 220.8 mm x 43.5 mm (13.0 in x 8.7 in x 1.7 in) Weight: 1.81 kg (4.0 lbs) Environmental Specifications Operating Temperature: 0° C to 40° C (32° F to 104° F) Storage Temperature: -25°...
  • Page 43: Safety And Electromagnetic Emissions Certifications

    AT-FS708/POE Fast Ethernet Switch Installation Guide Safety and Electromagnetic Emissions Certifications FCC Class A, CISPR 22 Class A, EN55022 Class A, C-TICK, CE Immunity EN55024 Electrical Safety UL 60950 ( ), EN60950 (TUV) or VDE Laser IEC/EN 60825-1, IEC/EN 60825-2 Compliance Standards IEEE 802.3 –...
  • Page 44: Rj-45 Twisted Pair Port Connectors

    RJ-45 Twisted Pair Port Connectors This section lists the connectors and connector pinouts for the AT-FS708/POE Fast Ethernet switch and its components. Figure 16 illustrates the pin layout to an RJ-45 connector and port. Figure 16. RJ-45 Connector and Port Pin Layout Table 4 lists the RJ-45 pin signals when a twisted pair port is operating in the MDI configuration.
  • Page 45: Translated Safety Statements

    Appendix B Translated Safety Statements Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Importante: Este apéndice contiene traducciones en múltiples idiomas de los mensajes de seguridad incluidos en esta guía.
  • Page 46: Laser Safety Notices

    Appendix B: Translated Safety Statements Laser Safety Notices Warning: Class 1 Laser product. Warning: Do not stare into the laser beam. Electrical Safety Notices Warning: To prevent electric shock, do not remove the cover. No user-serviceable parts inside. This unit contains hazardous voltages and should only be opened by a trained and qualified technician.
  • Page 47 AT-FS708/POE Fast Ethernet Switch Installation Guide Warning: Check to see if there are any exposed copper strands coming from the installed wire. When this installation is done correctly there should be no exposed copper wire strands extending from the terminal block. Any exposed wiring can conduct harmful levels of electricity to persons touching the wires.
  • Page 48 Use dedicated power circuits or power conditioners to supply reliable electrical power to the device. Warning: The chassis may be heavy and awkward to lift. Allied Telesyn recommends that you get assistance when mounting the chassis in an equipment rack.
  • Page 49: Telecommunications Compliance Notices

    AT-FS708/POE Fast Ethernet Switch Installation Guide Telecommunications Compliance Notices Warning: When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electronic shock, and injury to persons, including the following: Do not use this product near water, for example, near a bathtub, washbowl, kitchen sink, or laundry tub in a wet basement or near a swimming pool.
  • Page 50 Appendix B: Translated Safety Statements Lasersicherheitshinweise Achtung: Laserprodukt der Klasse 1. Achtung: Blicken Sie nicht in den Laserstrahl. Elektrische Sicherheitshinweise Achtung: Um Stromschläge zu vermeiden, darf die Abdeckung nicht entfernt werden. Die Ausrüstung enthält keine benutzerwartbaren Teile. Diese Einheit führt gefährliche Spannungen und sollte nur durch einen ausgebildeten und qualifizierten Techniker geöffnet werden.
  • Page 51 AT-FS708/POE Fast Ethernet Switch Installation Guide Achtung: Nicht mehr als die empfohlene Kabellänge abisolieren. Durch das Abisolieren von mehr als der empfohlenen Länge können gefährliche blanke Drähte aus dem Anschlussblock hervorragen. Achtung: Beim Installieren dieser Ausrüstung ist stets darauf zu achten, dass die Rahmenerdung zuerst angeschlossen und zuletzt abgetrennt wird.
  • Page 52 Zur zuverlässigen Stromversorgung des Geräts sollte ein dedizierter Stromkreis oder Netzfilter und Stabilisator (Power Conditioner) verwendet werden. Achtung: Das Chassis kann schwer und schwierig zu heben sein. Allied Telesyn empfiehlt, bei der Rackmontage des Chassis Hilfspersonal heranzuziehen. Achtung: Sehen Sie nicht direkt auf die Enden der Faseroptikkabel und inspizieren Sie die Kabelenden nicht mit einer optischen Linse.
  • Page 53 AT-FS708/POE Fast Ethernet Switch Installation Guide Telekommunikationskonformitätshinweise Achtung: Bei der Verwendung Ihrer Telefonausrüstung sollten zur Reduzierung der Brand-, Stromschlag und Verletzungsgefahr stets grundsätzliche Sicherheitsrichtlinien, einschließlich der folgenden, befolgt werden: Verwenden Sie dieses Produkt nicht in der Nähe von Wasser, zum Beispiel in der Nähe einer Badewanne, einer Waschschüssel, eines Spülbeckens, eines...
  • Page 54 Appendix B: Translated Safety Statements Avisos de seguridad láser Atención: Producto láser de clase 1. Atención: No mire el rayo láser. Avisos de seguridad eléctricas Atención: Para evitar la electrocución, no quite la tapa. La unidad no contiene piezas que pueda reparar el usuario. Esta unidad contiene tensiones peligrosas y sólo la debe abrir un técnico convenientemente formado y cualificado.
  • Page 55 AT-FS708/POE Fast Ethernet Switch Installation Guide Atención: Cuando instale el equipo, asegúrese de instalar primero la conexión a tierra del bastidor y de desconectarla en último lugar. Atención: Compruebe si hay algún hilo de cobre al descubierto que proceda del cable instalado.
  • Page 56 Utilice circuitos de alimentación dedicados o acondicionadores de alimentación para suministrar energía eléctrica fiable al dispositivo. Atención: El chasis puede ser pesado y difícil de levantar. Allied Telesyn recomienda buscar ayuda para montar el chasis en un rack. Atención: No mire directamente los extremos del cable de fibra óptica ni los inspeccione con una lente óptica.
  • Page 57 AT-FS708/POE Fast Ethernet Switch Installation Guide Avisos de conformidad de telecomunicaciones Atención: Cuando utilice su equipo telefónico, deberá adoptar las siguientes precauciones de seguridad básicas para reducir el riesgo de incendio, descarga electrónica y lesiones: No utilice este producto en zonas húmedas; por ejemplo, cerca de una bañera, un lavabo o un fregadero, en un sótano húmedo o cerca de una piscina.
  • Page 58 Appendix B: Translated Safety Statements Avis de sécurité laser Avertissement: Produit laser de classe 1. Avertissement: Ne pas observer directement le rayon laser. Avis de sécurité électrique Avertissement: Pour éviter tout risque d’électrocution, ne pas déposer le capot. L’appareil ne contient aucun composant réparable par l’utilisateur. Il est exposé à des tensions dangereuses et ne doit être ouvert que par un technicien compétent et qualifié.
  • Page 59 AT-FS708/POE Fast Ethernet Switch Installation Guide Avertissement: Respecter les recommandations pour dénuder les fils. Un dénudage excessif risque de présenter des risques pour la sécurité en laissant le fil exposé sur le bornier après l’installation. Avertissement: Lors de l’installation de cet équipement, toujours s’assurer que la connexion de terre de la structure est installée en premier et déconnectée en dernier.
  • Page 60 Utiliser des circuits d’alimentation ou des unités de conditionnement dédiés pour fournir une alimentation électrique fiable à l’équipement. Avertissement: Le châssis peut être lourd et difficile à soulever. Allied Telesyn recommande de demander de l’aide pour installer le châssis dans un rack.
  • Page 61 AT-FS708/POE Fast Ethernet Switch Installation Guide Télécommunications – Avis de conformité Avertissement: Les précautions élémentaires de sécurité doivent être systématiquement respectées en utilisant l’équipement téléphonique pour réduire les risques d’incendie, d’électrocution et d’accident corporel, notamment: Ne pas utiliser ce produit près d’une source d’eau, telle qu’une baignoire, un lavabo, un évier ou un baquet dans un sous-sol humide ou près d’une piscine.
  • Page 62 Appendix B: Translated Safety Statements Indicazioni sulla sicurezza laser Avvertenza: Prodotto laser Classe 1. Avvertenza: Non fissare il raggio laser. Indicazioni sulla sicurezza elettrica Avvertenza: Per evitare scosse elettriche, non rimuovere la copertura. All'interno non sono presenti componenti utilizzabili dall'utente. Questa unità presenta voltaggi rischiosi e deve essere aperta solo da un tecnico qualificato ed esperto.
  • Page 63 AT-FS708/POE Fast Ethernet Switch Installation Guide Avvertenza: Quando si installa l'apparecchiatura, verificare che il collegamento di messa a terra FG (frame ground) sia installato per primo e disinstallato per ultimo. Avvertenza: Verificare che non sporgano fili di rame dai cavi installati. Se l'installazione viene effettuata correttamente, non vi sono fili di rame scoperti, sporgenti dal blocco terminale.
  • Page 64 Appendix B: Translated Safety Statements Avvertenza: Rimuovere tutti gli oggetti di metallo, ad esempio anelli e orologi, prima di installare o estrarre una scheda di linea da un chassis acceso. Utilizzare circuiti di alimentazione o alimentatori dedicati per fornire energia elettrica al dispositivo in modo affidabile.
  • Page 65 AT-FS708/POE Fast Ethernet Switch Installation Guide Indicazioni per la conformità con le norme sulle telecomunicazioni Avvertenza: Quando si utilizza l'apparecchiatura telefonica, per ridurre il rischio di incendio, scosse elettriche e danni alle persone, è necessario seguire alcune precauzioni di base per la sicurezza, ad esempio: Non utilizzare il prodotto in prossimità...
  • Page 66 Appendix B: Translated Safety Statements Лазерная безопасность Внимание: лазерный продукт, класс 1. Внимание: Не смотрите прямо в лазерный луч. Электрическая безопасность Внимание: Для предотвращения электрического шока, не снимайте кожух. Внутри нет частей, подлежащих обслуживанию пользователем. Этот устройство – под опасным напряжением и должно открываться только обученным и квалифицированным...
  • Page 67 AT-FS708/POE Fast Ethernet Switch Installation Guide Внимание: При инсталляции оборудования, убедитесь, что заземление подключается в первую, а отключается в последнюю очередь. Внимание: Проверьте, нет ли на инсталлированных проводков на кабеле. При правильной инсталляции на терминале свободных проводков быть не должно.
  • Page 68 Для надежного питания используйте отдельные контуры питания и выравниватели энергии. Внимание: Корпус может быть тяжелым и поднять его может быть сложно. Allied Telesyn рекомендует, что при установке корпуса на раме Вам необходимо обеспечить соответствующую помощь. Внимание: Не смотрите прямо на торцы волоконно-оптического кабеля и не...
  • Page 69 AT-FS708/POE Fast Ethernet Switch Installation Guide Телекоммуникационное соответствие Внимание: При использовании телефонного оборудования, всегда следует обращать внимания на требования безопасности для снижения риска пожара, поражения током и ранения, в том числе: Не используйте оборудование рядом с водой – например ванной, раковиной или...

Table of Contents