Replacing The Top Cover; Installing The Raid Battery - HP Integrity rx2660 User's & Service Manual

Hide thumbs Also See for Integrity rx2660:
Table of Contents

Advertisement

RAID battery port on
1
the SAS Smart Array
controller
SAS Smart Array
2
P400 controller board
lock
5.
To install the RAID battery onto the airflow guide, follow these steps:
a.
Align the tabs on the RAID battery with the slots on the airflow guide.
b.
Slide the RAID battery toward the rear of the server until the locking clip locks the
RAID battery in place (1).
onto the airflow guide.
Figure 3-19 Installing the RAID battery
6.
Connect one end of the RAID battery cable to the battery on the airflow guide.
7.
Connect the other end of the RAID battery cable to the SAS Smart Array P400 controller.
CAUTION:
reconnecting these cables, match each cable with the appropriate socket on the SAS Smart Array
P400 controller board. If the cables are mismatched, the server may not reboot. Both cables and
sockets are clearly marked with the correct channels.

Replacing the Top Cover

To replace the top cover, follow these steps:
1.
Ensure the cover release lever is in the open position.
replace the top cover.
2.
Align the tabs of the top cover with the corresponding slots in the chassis and insert the tabs
into the slots (1).
3.
Slide the cover forward until it is flush with the front of the chassis (2).
4.
Push the cover release lever down into the latched position (3).
When disconnecting the SAS cables, note the labeling on the cables. When
SAS Smart Array
3
P400 controller
Figure 3-19 (page 63)
shows how to lock the RAID battery
SAS cable ports on the
4
SAS Smart Array P400
controller
Figure 3-20 (page 64)
shows how to
Installing Additional Components