Figure 3-21 Rear Panel Control, Port, and LED Locations
Power supply 1 and LED
1
Power supply 2 and LED
2
PCI-X/PCIe slots
3
Core LAN ports
4
Smart Array P400
5
controller slot
NOTE:
The Office Friendly server is shown in
may only have one power supply installed.

Applying Standby Power to the Server

To apply standby power to the server, follow these steps:
1.
If the server has one power supply installed in slot P1, plug the power cord into that
receptacle. Plug the other end of the power cord into an appropriate outlet.
NOTE:
LED illuminates green when the server is powered on to full power.
If the power restore feature is set to Always On through the iLO 2 MP PR command, the
server automatically powers on to the full power state when the power cord is plugged into
the server.
2.
If the server has two power supplies, plug the second power cord into the power supply in
slot P2. Plug the other end of the power cord into an appropriate outlet.

Connecting to the LAN

The server has two LAN ports that provide network connectivity.
the available LAN ports for the server.
To enable general network connectivity for the server, follow these steps:
1.
Obtain valid IP addresses for each LAN port you plan to activate.
66
Installing the Server
6
7
8
9
The LED on the power supply does not illuminate in the standby power state. The
Auxiliary serial port
VGA port
USB ports
Console serial port
Figure 3-21 (page
iLO 2 MP LAN port
10
iLO 2 MP status LEDs
11
iLO 2 MP reset
12
UID button/LED
13
66). The Data Center server