Rdv3611 Flue Components - Rinnai Symmetry RDV3611 Installation Manual

Hide thumbs Also See for Symmetry RDV3611:
Table of Contents

Advertisement

RDV3611 flue components

165
Flue elbow 90 °
Code
= R3643
Used to facilitate vertical and
horizontal flueing. Elbow
swivels 360 ° at base. Angle not
adjustable.
Once joined effective length
reduces 35 mm.
90 ° = 130 mm
45 degree offsets
14 | RDV3611 Installation Manual: 11156-A 01-12
108
108
165
Flue elbow 45 °
Code
= R3642
Offsets obstructions. Elbow
swivels 360 ° at base. Angle
not adjustable. Kit contains two
45 ° bends.
Once joined effective length
reduces 35 mm.
45 ° = 73 mm
Flue pipe (length and code)
None (bend to bend)
N/A
150 mm
R3630
230 mm
R3631
300 mm
R3632
450 mm
R3633
600 mm
R3634
900 mm
R3635
1200 mm
R3636
Flue pipes
Codes
150 mm
= R3630
230 mm
= R3631
300 mm
= R3632
450 mm
= R3633
600 mm
= R3634
900 mm
= R3635
1200 mm
= R3636
Pipe used to construct
horizontal and vertical flueing.
Cannot be cut to size. Once
joined nominal length reduces
approx. 35 mm.
Offset (mm)
Rise (mm)
124
340
203
419
257
473
311
527
417
633
524
740
737
953
949
1165

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents